Installation

Should any anomaly occur in the condensation water 
system, the maximum level float blocks the conditioner and 
the OF code appears on the display. 
During cooling and dehumidification, electronics switches 
the compressor off and keeps the water distribution system 
active with the battery - together with the fan - to disperse 
excess water in the container. If the problem persists, please 
contact the assistance service.
During heating, condensations should drain freely through 
the specific pipe. In the event of an alarm, check that the 
condensation pipe is not bent or obstructed, thus preventing 
the water from flowing out.

If the presence contact is not closed, the appliance doesn't 
start and the CP alarm appears on the display.

The key lock is activated by keeping the Timer 

 symbol on 

the touch-screen display pressed for three 

seconds.  

Operating aspects that must not be interpreted as problems 
Managing the appliance if the remote control is not available.
To deactivate the lock, keep the Timer symbol pressed for three 
seconds once again.
The lock remains active also for the next operations performed 
via remote control and in the event of a power failure.

Press and hold the air exchange key ( 

 ) for 10 seconds to 

enable the function ("En" displayed); the dehumidification 
and Auto functions are disabled (leaving active only 
ventilation, heating and cooling) and the settable set range is 
reduced from 22 to 28 in cooling mode and from 16 to 24 in 
heating mode.

The display brightness sensor can be disabled (leaving the 
maximum brightness at all times) by pressing and holding 
the night button  ( 

 ) for 10 seconds. "ds" (disabled) or 

"En" (enabled) will appear on the display.

Display 
indications

Cause

E1

Broken room temperature RT probe 

E2

Broken evaporative battery IPT probe

E3

Broken outdoor air temperature OT probe

E4

Broken conditioner battery OPT probe

E5

Broken indoor air fan motor

E6

Broken outdoor air fan 

E7

Lack of communication with the display

E8

Compressor discharge probe failure (only for DC Inverter models) 

If the conditioner blocks because of an alarm (see following 
table), please communicate to the assistance centre the code 
on the display to facilitate interventions.

It is possible to deactivate the heating or the cooling modes 
following a simple procedure.
Keep the A key on the touch-screen display pressed for 
5 seconds until HC (heating and cooling) appears on the 
display.
Press the A key for 1 second for the Co (cooling only) mode.
Press the A key again for Ho (heating only) mode.
Wait for 3 seconds without touching anything to memorise 
the setting.

Setting cool only or heat only modes

Brightness regulation

Touch-screen display key lock

Hotel function

Anomaly diagnosis

Open CP contact

Evacuation of condensate water in the event of an emergency

Содержание Soloclim SC17

Страница 1: ...Soloclim Original instructions Installation ...

Страница 2: ...zardous substances in electrical and electronic equipment 2011 65 EC RoHS2 Waste electrical and electronic equipment 2002 96 EC WEEE Energy consumption indication on the labels of energy related products 2010 30 EU Warning It indicates actions that require caution and a suitable preparation Prohibition Refers to prohibited actions Compliance Safety pictograms ...

Страница 3: ...t 8 Assembling the unit 9 Condensation drain predisposition 10 Assembling air ducts and external shutters 10 Mounting the appliance on the bracket 11 Electrical connection 12 High low installation configuration 13 Setting cool only or heat only modes 14 Brightness regulation 14 Touch screen display key lock 14 Hotel function 14 Anomaly diagnosis 14 Troubleshooting Periodic Maintenance 16 Troublesh...

Страница 4: ...n without supervision It is forbidden to modify the safety or adjustment devices or adjust without authorisation and indications of the manufacturer It is forbidden to pull out or twist the electric cables coming out of the unit even when disconnected from the mains power supply General General warnings A temperature that is too high or too low is harmful to health and is an unnecessary waste of e...

Страница 5: ...he packing list check that none of the parts have been damaged during shipment In case of damage report it to the shipping company within 3 days of receipt by registered letter with return receipt and attaching photographic documentation A copy should also be sent by fax to the MANUFACTURER No notice of damage will be accepted after 3 days from delivery Description Storage The energy consumption i...

Страница 6: ...holes G CR2025 3V remote control battery H Wall inlet pipes 2 pcs I Energy efficiency label N Installation manual O Counter flange for internal wall The unit is packed singularly in a cardboard box Boxes can either be carried singularly by hand by two operators or loaded on a cart for a maximum of three units w Handling must be performed by qualified personnel with specific tools and with equipmen...

Страница 7: ...h screen display 3 Front panel 4 Outdoor air suction 5 Outdoor air outlet 6 Internal air intake grille 7 Air Filter 8 Condensation drain pipe 9 Room air probe 10 Power supply terminal board 11 Aesthetic side panel 12 Anti lifting bracket Unit parts ...

Страница 8: ...e must be installed against a wall communicating with the outside The appliance is declared to have a degree of protection IPX0 therefore it is not suitable for outdoor installation Installation Installation mode Choosing the position of the unit Try to reduce the thermal refrigeration load of the room following instructions below Cover large windows exposed to sunlight with curtains or with exter...

Страница 9: ...m Holes for air channelling D Ø14 mm Condensation drain E Anti lifting bracket hole The majority of the removed material is expelled outwards so please be careful that it doesn t hit people or objects In order to avoid breaking the outer plaster be careful while drilling the final part of the hole and ease the pressure on the core drill Drill the 6 holes for the bracket as indicated on the templat...

Страница 10: ...shutters insert your arm in the hole to push the shutter outside while holding the ends of the chains with the other hand to prevent them from falling down open the shutter inside the hole rotate the shutter to bring the flap in the vertical C position and check that the closing mechanism works pull the chains by tensioning the springs use a bolt cutter to remove any excess chain anchor the hook o...

Страница 11: ...omplete check their opening towards the inside of the duct for the air inlet grid IN and towards the outside of the duct for the air outlet grid OUT Remember that the grilles open when the external air flow is activated to allow the cooling and heating functions to be operated The conditioner must be activated for cooling or heating in order to test them Mounting the appliance on the bracket carri...

Страница 12: ...contact opens very low voltage connected to a free non live contact the appliance is put is stand by and CP appears on the display Using this contact it is possible to connect an external device that inhibits the functioning of the appliance such as open window contact on off remote infrared presence sensors enabling badge etc We recommend using a double insulation cable A 230V 50 Hz Electrical po...

Страница 13: ... it is necessary to set up the electronic control of the appliance Keep pressed the button on the display for 5 seconds The dn lower wall symbol flashes on the display Press the key again The uP upper wall symbol lights up on the display If no other operations are performed in the following 2 seconds the new setting is memorised A High installation B Low installation factory settings 1 Block inser...

Страница 14: ...ion and Auto functions are disabled leaving active only ventilation heating and cooling and the settable set range is reduced from 22 to 28 in cooling mode and from 16 to 24 in heating mode The display brightness sensor can be disabled leaving the maximum brightness at all times by pressing and holding the night button for 10 seconds ds disabled or En enabled will appear on the display Display ind...

Страница 15: ...hich are not strictly necessary in any case allow for a more professional appearance of the installation in the eyes of the User To avoid unnecessary calls by the User before leaving the site it is also a good idea to show them the contents of the Manual show them how to clean the filter explain when and how they should contact Customer Service Use of the appliance During heating mode the conditio...

Страница 16: ...wish to start up the appliance after a period of inactivity N B before performing any operation take care with the hot and or sharp surfaces of the metal The filter is placed in the top part of the appliance To extract the filters open the grid and remove it extract the filters by lifting them remove the dust from the filter with a vacuum cleaner or by washing it in running water without using det...

Страница 17: ...ot of heat Try to reduce the thermal refrigeration load of the room following instructions below Cover large windows exposed to sunlight with curtains or with external maskings blinds porches reflecting films etc The room must remain closed for as long as possible Avoid turning on halogen lamps or other high energy consumption appliances such as small ovens steam irons cooking plates etc Alarm Cau...

Страница 18: ... A Energy efficiency ration when heating A A A A Internal external ventilation speed No 3 3 3 3 Dimensions WxHxD mm 1030x555x170 1030x555x170 1030x555x170 1030x555x170 Weight kg 47 6 48 0 48 5 48 5 Noise level min max dB A 29 38 32 41 27 41 27 41 Wall holes diameter mm 162 162 162 162 Wall holes distance mm 293 293 293 293 Refrigerant gas R 410A R 410A R 410A R 410A R410A refrigerant charge g 480 ...

Страница 19: ...Main office Frico AB Tel 46 31 336 86 00 Box 102 SE 433 22 Partille mailbox frico se Sweden www frico se For latest updated information and information about your local contact www frico se ...

Отзывы: