14
Soloclim
GB
Installation
Should any anomaly occur in the condensation water
system, the maximum level float blocks the conditioner and
the OF code appears on the display.
During cooling and dehumidification, electronics switches
the compressor off and keeps the water distribution system
active with the battery - together with the fan - to disperse
excess water in the container. If the problem persists, please
contact the assistance service.
During heating, condensations should drain freely through
the specific pipe. In the event of an alarm, check that the
condensation pipe is not bent or obstructed, thus preventing
the water from flowing out.
If the presence contact is not closed, the appliance doesn't
start and the CP alarm appears on the display.
The key lock is activated by keeping the Timer
symbol on
the touch-screen display pressed for three
seconds.
Operating aspects that must not be interpreted as problems
Managing the appliance if the remote control is not available.
To deactivate the lock, keep the Timer symbol pressed for three
seconds once again.
The lock remains active also for the next operations performed
via remote control and in the event of a power failure.
Press and hold the air exchange key (
) for 10 seconds to
enable the function ("En" displayed); the dehumidification
and Auto functions are disabled (leaving active only
ventilation, heating and cooling) and the settable set range is
reduced from 22 to 28 in cooling mode and from 16 to 24 in
heating mode.
The display brightness sensor can be disabled (leaving the
maximum brightness at all times) by pressing and holding
the night button (
) for 10 seconds. "ds" (disabled) or
"En" (enabled) will appear on the display.
Display
indications
Cause
E1
Broken room temperature RT probe
E2
Broken evaporative battery IPT probe
E3
Broken outdoor air temperature OT probe
E4
Broken conditioner battery OPT probe
E5
Broken indoor air fan motor
E6
Broken outdoor air fan
E7
Lack of communication with the display
E8
Compressor discharge probe failure (only for DC Inverter models)
If the conditioner blocks because of an alarm (see following
table), please communicate to the assistance centre the code
on the display to facilitate interventions.
It is possible to deactivate the heating or the cooling modes
following a simple procedure.
Keep the A key on the touch-screen display pressed for
5 seconds until HC (heating and cooling) appears on the
display.
Press the A key for 1 second for the Co (cooling only) mode.
Press the A key again for Ho (heating only) mode.
Wait for 3 seconds without touching anything to memorise
the setting.
Setting cool only or heat only modes
Brightness regulation
Touch-screen display key lock
Hotel function
Anomaly diagnosis
Open CP contact
Evacuation of condensate water in the event of an emergency