Installation
The unit can be installed either in the lower part (near the
floor) or in the upper part (near the ceiling) of the wall. In
order to optimise air distribution and comfort, the direction
of the air flow can be modified by adjusting the position of
the air flap.
The appliance is supplied ready to be installed in the lower
part of the wall, so air is dispensed upwards.The same
• Open the air outlet flap gently
• Remove the flap opening block insert located internally
on the right of the air outlet mouth and place it in the
lower hole.
• Remove the upper grill
• Remove the two plastic side panels by moving them up
• Unscrew the fixing screws
• Remove the front panel
• Place the bottom cover and fix it with the supplied
screws (optional kit GB0737)
• Refit in the reverse order.
After adjusting the air outlet flap position, it is necessary to
set up the electronic control of the appliance:
-
Keep pressed the
button on the display for 5
seconds;
-
The
dn
(lower wall) symbol flashes on the display;
-
Press the
key again;
-
The
uP
(upper wall) symbol lights up on the display.
-
If no other operations are performed in the following 2
seconds, the new setting is memorised.
A
High installation
B
Low installation (factory settings)
1
Block insert
2
Lower cover (kit code GB0737)
3
Fixing screws (supplied with the optional kit GB0737)
4
Upper grill
5
Plastic side panels
6
Front panel
High/low installation configuration
configuration can also be used in the upper part of the wall
in cooling mode, which increases the air flow in the room
(coanda effect).
In this case, purchase the the lower cover aesthetic kit code
GB0737.
This operation must be performed while the appliance is
switched off and disconnected.
Modifications from lower wall to the upper wall position
For the appliance to work properly, each time the
configuration of the air outlet flap is modified, the
electronic control must be set.