25 Locust St, Haverhill, Massachusetts 01830 • Tel: 800/252-7074, 978/374-0761 • FAX: 978/521-1839
e-mail: [email protected] • Web Address: http://www.freqdev.com
SPPDF-01 Development Suite
User’s Manual
FCG Immediate Mode Operation
Single Set Coefficient
Appendix A - Example 2
12.3. Go Command Button: CLICK Go and the plot panel window will close and execu-
tion will return to the main panel.
12.4. Stop Command Button: CLICKING Stop will close the plot panel window and
return user to the main panel.
13. Note: CLICK Go command button after inspecting the amplitude/phase characteristics
representations to close the plot panel window and return to the main panel. You may
also CLICK the Stop command button to get to the main panel. The Message indicator
shows the number of filters designed. For this example it is one (1).
14. Inspect results: At the MatLab
TM
environment prompt type: whos. The system will
respond with the information for the coefficients variable:
Name
Size
Bytes
Class
coefficients
1x299
2392
double array (global)
Grand total is 299 elements using 2392 bytes
IMPORTANT
Remember: When clearing or quitting the workspace, the coefficients data will be
lost unless the variables are saved to the workspace. After saving them, the coeffi-
cients may be used as desired: i.e. loading into the SPPDM-01 platform, mathemati-
cal transformation, inspection, etc. Follow MatLab
TM
’s and the FCL’s instructions for
performing these tasks.
References:
1.1. The Mathworks, Using MatLab
TM
Graphics
1.2. The Mathworks, Building GUI’s with MatLab
TM
1.3. The Mathworks, Using MatLab
TM
1.4. The Mathworks, MatLab
TM
Function Reference
1.5. The Mathworks, Application Program Interface (API) Guide
1.6. The Mathworks, Application Program Interface (API) Reference
1.7. SPPDF-01 Operation/User Manual
SPPDB-01 Specifications Sheets
18