Boiler Manual
32
Troubleshooting
(continued)
Table 5
FreeStyle
LISTOF3YSTEMPARAMETERSDEFAULTSETTINGS
System Parameters list (default settings)
There are 4 basic configurations within the DHW mode, selected by parameter DHW configuration (see Parameters list, Num.
$EFAULTVALUEISANDITREPRESENTSCONlGURATION"YCHANGING$(7CONlGURATIONSEE0ARAMETERSLIST.UM ALLTHEDATA
WILLBEAUTOMATICALLYSETATDEFAULTCONDITION0ARAMETERSTHATWILLBECHANGEDACCORDINGTOTHE$(7MODEARENUMBEREDFROM
to 46 (see Parameters list). All the parameters can be accessed with a communication package running on the PC. Some param-
ETERSAREAVAILABLEBYTHEINSTALLER430MODEONTHE--)ORBYTHE/42OOMUNIT
Category
%PROMPARAMETERS
Unit
2ANGE
$EF
Description
Num.
Address
Description
Low
High
Value
DHW boiler type
1
CL5 – 05C8
'+:FRQ¿JXUDWLRQ
Num
1
4
3
System
2
ML – 80D0
)LUVWVWDUWXSÀDJ
Num
0
1
0
End user setting
3
ML – 80E2
Summer / Winter selection
Num
0
1
1
End user setting
4
ML – 80E3
Economy / Comfort selection
Num
0
1
0
End user setting
5
CL5 – 0A9D
CH set point limit - HIGH
°F
68
194
190
End user setting
6
CL5 – 056D
CH user set point
°F
68
194
158
Exhaust protection
7
CL5 – 050B
Maximum exhaust gases temperature
°F
32
255
185
Firmware version
8
ML – 80E8
Firmware version
Num
0
99
01
'+:FRQ¿J
9,1
CL5 – 066E
DHW P factor
Num
0
255
15
'+:FRQ¿J
10,1
CL5 – 0691
DHW I factor
Num
0
255
240
'+:FRQ¿J
11,1
ML – 80EB
DHW FF factor
Num
0
255
0
'+:FRQ¿J
12,1
ML – 80EC
Fan absolute DHW maximum speed
Hz
0
220
200
'+:FRQ¿J
13,1
ML – 80ED
Fan absolute CH maximum speed
Hz
0
220
200
'+:FRQ¿J
14,1
ML – 80EE
Fan absolute minimum speed
Hz
0
165
40
'+:FRQ¿J
15,1
CL5 – 2D89
Fan offset low level
Hz
0
220
10
'+:FRQ¿J
16,1
ML – 80F0
Ignition level
%
0
100
60
'+:FRQ¿J
17,1
ML – 80F1
DHW maximum output boost/limit level
%
75
125
100
'+:FRQ¿J
18,1
ML – 80F2
DHW maximum output boost/limit time
Sec
0
120
60
'+:FRQ¿J
19,1
ML – 80F3
'+:RYHUWHPSBEXUQHU2))¿[HG
°F 68
194
167
'+:FRQ¿J
20,1
ML – 80F4
'+:RYHUWHPSBEXUQHU21¿[HG
°F 68
194
163
'+:FRQ¿J
21,1
ML – 80F5
DHW over-temp_burnerOFF – setpoint
°F
0
200
9
'+:FRQ¿J
22,1
ML – 80F6
DHW over-temp_burnerON – setpoint
°F
0
200
0
'+:FRQ¿J
23,1
ML – 80F7
DHW over-temp_burnerOFF – solar
°F
0
200
18
'+:FRQ¿J
24,1
ML – 80F8
DHW over-temp_burnerON – solar
°F
0
200
18
'+:FRQ¿J
25,1
ML – 80F9
DHW start waiting time – solar1
Sec
0
255
5
'+:FRQ¿J
26,1
ML – 80FA
DHW start waiting time – solar2
Sec
0
255
10
'+:FRQ¿J
27,1
ML – 80FB
DHW start waiting time – solar3
Sec
0
255
20
'+:FRQ¿J
28,1
CL5 – 0A5E
DHW comfort switch on point
°F
0
176
104
'+:FRQ¿J
29,1
CL5 – 0A62
DHW comfort on time
Sec
0
104
15
'+:FRQ¿J
30,1
ML – 80FE
DHW comfort off time1
Min
0
255
20
'+:FRQ¿J
31,1
ML – 80FF
DHW comfort off time2
Min
0
255
42
'+:FRQ¿J
32,1
CL5 – 05A1
DHW OFF time
Sec
30
255
120
'+:FRQ¿J
33,1
CL5 -0A04
DHW pump over-run time
Sec
0
255
3
'+:FRQ¿J
34,1
CL5 – 0A6D
Delta T1
°F
0
108
32
'+:FRQ¿J
35,1
CL5 – 0A92
Delta T2
°F
0
255
63
&IGURE
4ROUBLESHOOTINGSUGGESTIONSFOR
FreeStyle
™
BOILERS
&AULTDISPLAYSANDDIAGNOSTICS
(continued)