Part number 550-142-850/0115
54
FreeStyle
™
W
ALL
M
OUNT
GAS
-
FIRED
WATER
BOILER
—
Boiler Manual
23
Wiring diagram — Heating Only Ladder
Figure 70
FreeStyle
™
(EATING/NLY,ADDER7IRING$IAGRAM
Legend
16 Fan
32
Central heating pump (not included)
44
Gas valve
72
Room thermostat (optional)
81
Ignition electrode
104(1) Fuse 3.15A
104(1) Fuse 630mA
114
Water pressure switch
130
DHW Pump (not included)
138 Outdoor
sensor
143
DHW tank thermostat (optional)
186
Return temperature sensor
191
Exhaust temperature sensor
278
Double sensor (h safety)
279
Transformer 115-24 Vac
284
Relay SPST-Coil 24 Vac
370 LWCO
(optional)
373 “OPENTHERM”
communication
(Not used)
NOTES:
1.
All wiring must be installed
in accordance with N.E.C.
and any other national state
or local requirements.
2.
Room thermostat should
be a dry contact type and
should draw power from the
control board: should not
be greater than 24 Vac and
500 mA.
3.
Max. voltage and electric
current for the LWCO +
CH PUMP + DHW PUMP
should not be greater than
120 Vac and 3 Amp.
4.
In case of questions during
installation please contact
your local W-T distributor.