![Freestyle FS-120 LP Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/freestyle/fs-120-lp/fs-120-lp_instruction-manual_2330823012.webp)
Part number 550-142-850/0115
12
FreeStyle
™
W
ALL
M
OUNT
GAS
-
FIRED
WATER
BOILER
—
Boiler Manual
4 Converting boiler to propane
Prepare boiler for propane
(if
required)
FreeStyle
™ 80/120
Propane operation
!,,
FreeStyle
™
boilers must be
CONVERTEDFORPROPANEOPERATION
.
Converting an existing natural gas-
lREDBOILERFORPROPANE
— For a boiler
ALREADY INSTALLED YOU MUST TURN OFF GAS
SUPPLY TURN OFF POWER AND ALLOW BOILER
TO COOL BEFORE PROCEEDING9OU MUST ALSO
COMPLETELYTESTTHEBOILERAFTERCONVERSION
TOVERIFYPERFORMANCEANDSTARTUPTHEBOILER
FOLLOWINGINSTRUCTIONSBEGINNINGON
page 66
OFTHISMANUAL
6ERIFY#ONVERSIONKIT
—See Figure 8.
LP gas venturi will have a black label
and will be clearly labeled “
LPG
”.
Natural gas venturi will have a white label
and will be clearly labeled “
NG
”.
Failure to comply could result in severe per-
sonal injury, death or substantial property
damage.
Figure 8
.ATURALAND,IQUElED0ETROLEUM0ROPANE GAS
CONVERSIONKITS
Boiler
model
Kit
PARTNUMBER
&3.'
640-000-022WT
&3,0
640-000-024WT
&3.'
640-000-023WT
&3,0
640-000-025WT
This conversion kit shall be installed by a qualified
service agency in accordance with the
manufacturer’s instructions and all applicable codes
and requirements of the authority having jurisdiction.
If the information in these instructions is not followed
exactly, a fire, an explosion or production of carbon
monoxide may result causing property damage,
personal injury or loss of life. The qualified service
agency is responsible for the proper installation of this
kit. The installation is not proper and complete until
the operation of the converted appliance is checked as
specified in the manufacturer’s instructions supplied
with the kit.
s
Follow all instructions in proper order.
s $O NOT TAMPER WITH VENTURI $/ ./4 CHANGE OR MODIFY
venturi in any way.
s
Do not leave an uninstalled venturi in the building.
s #AUTIONTHEGASSUPPLYSHALLBESHUTOFFPRIORTODISCONNECTING
THEELECTRICALPOWERBEFOREPROCEEDINGWITHTHECONVERSION
&3.'
P/N 640-000-022WT LP to Natural Gas Conversion Kit contents:
36602390
Venturi - Natural Gas D.22 UG.D.3
1
35105080
Gasket Nitrile Rubber 167 x 63.5X3.53 NBR
1
3541F210
Label Gas Conversion
1
3541G210 Label FS-80 Rating Plate Conversion NG
1
550-142-855 Instructions Conversion LP to Natural Gas
1
&3.'
P/N 640-000-023WT LP to Natural Gas Conversion Kit contents:
36602400
Venturi - Natural Gas D.22 UG.D.3
1
35105080
Gasket Nitrile Rubber 167 x 63.5X3.53 NBR
1
3541F210
Label Gas Conversion
1
3541G220 Label FS-120 Rating Plate Conversion LP
1
550-142-855 Instructions Conversion LP to Natural Gas
1
&3,0
P/N 640-000-024WT NG to Propane Gas Conversion Kit contents:
36602430
Venturi - D.22 UG.D.2.8 GPL
1
35105080
Gasket Nitrile Rubber 167 x 63.5X3.53 NBR
1
3541F210
Label Gas Conversion
1
3541G190 Label FS-80 Rating Plate Conversion LP
1
550-142-854 Instructions Conversion Nat to LP Gas
1
&3,0
P/N 640-000-025WT NG to Propane Gas Conversion Kit contents:
36602450
Venturi - D.22 UG.D.3.0 GPL
1
35105080
Gasket Nitrile Rubber 167 x 63.5X3.53 NBR
1
3541F210
Label Gas Conversion
1
3541G200 Label FS-120 Rating Plate Conversion LP
1
550-142-854 Instructions Conversion Nat to LP Gas
1