FlexRay Module (FLEXRAYV4)
MFR4310 Reference Manual, Rev. 2
92
Freescale Semiconductor
3.3.2.20
Protocol Status Register 2 (PSR2)
This register provides a snapshot of status information about the Network Idle Time NIT, the Symbol
Window and the clock synchronization. The NIT related status bits NBVB, NSEB, NBVA, and NSEA are
updated by the FlexRay module after the end of the NIT and before the end of the first slot of the next
Table 3-26. PSR1 Field Descriptions
Field
Description
15
CSAA
Cold Start Attempt Aborted Flag — Protocol related event: Set coldstart abort indicator in CHI’
This flag bit is set when the FlexRay modulehas aborted a cold start attempt. The application clears this flag by
writing 1 to it. Writing a 0 does not change the state of the flag. If the application clears the flag while the FlexRay
module sets the flag at the same time, then the flag is not cleared.
0 No such event
1 Cold start attempt aborted
14
CSP
Leading Cold Start Path — This status bit is set when the FlexRay module has reached the
POC:normal active
state via the leading cold start path. This indicates that this node has started the network
0 No such event
1
POC:normal active
reached from
POC:startup
state via leading cold start path
12–8
REMCSAT
Remaining Coldstart Attempts — protocol related variable:
vRemainingColdstartAttempts
This field provides the number of remaining cold start attempts that the FlexRay module executes.
7
CPN
Leading Cold Start Path Noise — protocol related variable:
vPOC!ColdstartNoise
This status bit is set if the FlexRay module has reached the
POC:normal active
state via the leading cold start
path under noise conditions. This indicates there was some activity on the FlexRay bus while the FlexRay
module was starting up the cluster.
0 No such event
1
POC:normal active
state was reached from
POC:startup
state via noisy leading cold start path
6
HHR
Host Halt Request Pending — protocol related variable:
vPOC!CHIHaltRequest
This status bit is set when FlexRay module receives the HALT command from the application via the
Operation Control Register (POCR)
. The FlexRay module clears this status bit after a hard reset condition or
when the protocol is in the
POC:default config
state.
0 No such event
1 HALT command received
5
FRZ
Freeze Occurred — protocol related variable:
vPOC!Freeze
This status bit is set when the FlexRay module has reached the
POC:halt
state due to the host FREEZE
command or due to an internal error condition requiring immediate halt. The FlexRay module clears this status
bit after a hard reset condition or when the protocol is in the
POC:default config
state.
0 No such event
1 Immediate halt due to FREEZE or internal error condition
4–0
APTAC
Allow Passive to Active Counter — protocol related variable:
vPOC!vAllowPassivetoActive
This field provides the number of consecutive even/odd communication cycle pairs that have passed with valid
rate and offset correction terms, but the protocol remains in the
POC:normal passive
state due to an application
configured delay to enter
POC:normal active
state. This delay is defined by the allow_passive_to_active field in
the
Protocol Configuration Register 12 (PCR12)
0x002C
Additional Reset: RUN Command
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R NBVB NSEB STCB SBVB SSEB MTB
NBVA NSEA STCA SBVA SSEA
MTA
CLKCORRFAILCNT
W
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Figure 3-19. Protocol Status Register 2 (PSR2)
Содержание FlexRay MFR4310
Страница 1: ...FlexRay Communication freescale com Controllers MFR4310RM Rev 2 03 2008 MFR4310 Reference Manual...
Страница 2: ......
Страница 3: ...MFR4310 Reference Manual MFR4310RM Rev 2 03 2008...
Страница 6: ...MFR4310 Reference Manual Rev 2 6 Freescale Semiconductor...
Страница 12: ...MFR4310 Reference Manual Rev 2 12 Freescale Semiconductor Section Number Title Page...
Страница 24: ...MFR4310 Reference Manual Rev 2 24 Freescale Semiconductor Table Number Title Page...
Страница 28: ...Introduction MFR4310 Reference Manual Rev 2 28 Freescale Semiconductor...
Страница 58: ...Device Overview MFR4310 Reference Manual Rev 2 58 Freescale Semiconductor...
Страница 222: ...Dual Output Voltage Regulator VREG3V3V2 MFR4310 Reference Manual Rev 2 222 Freescale Semiconductor...
Страница 234: ...Clocks and Reset Generator CRG MFR4310 Reference Manual Rev 2 234 Freescale Semiconductor...
Страница 260: ...Package Information MFR4310 Reference Manual Rev 2 260 Freescale Semiconductor...
Страница 267: ......