![Freescale Semiconductor FlexRay MFR4310 Скачать руководство пользователя страница 205](http://html1.mh-extra.com/html/freescale-semiconductor/flexray-mfr4310/flexray-mfr4310_reference-manual_2330597205.webp)
FlexRay Module (FLEXRAYV4)
MFR4310 Reference Manual, Rev. 2
Freescale Semiconductor
205
state. The application can observe this state change in the PROTSTATE field of the
3.7.2
Protocol Control Command Execution
This section considers the issues of the protocol control command execution.
The application issues any of the protocol control commands listed in the POCCMD field of
by writing the command to the POCCMD field of the
Protocol Operation Control Register (POCR)
result the FlexRay module sets the BSY bit while the command is transferred to the PE. When the PE has
accepted the command, the BSY flag is cleared. All commands are accepted by the PE.
The PE maintains a protocol command vector. For each command that was accepted by the PE, the PE sets
the corresponding command bit in the protocol command vector. If a command is issued while the
corresponding command bit is set, the command is not queued and is lost.
If the command execution block of the PE is idle, it selects the next accepted protocol command with the
highest priority from the current protocol command vector according to the protocol control command
priorities given in
. If the current protocol state does not allow the execution of this protocol
command (see POC state changes in
FlexRay Communications System Protocol Specification, Version 2.1
) the FlexRay module asserts the illegal protocol command interrupt flag IPC_IF in the
Interrupt Flag Register 1 (PIFR1)
. The protocol command is not executed in this case.
Some protocol commands may be interrupted by other commands or the detection of a fatal protocol error
as indicated by
. If the application issues the RESET, FREEZE, or READY command, or if the
the PE detects a fatal protocol error, some commands already stored in the command vector are removed
from this vector.
Table 3-112. Protocol Control Command Priorities
Protocol Command
Priority
Interrupted By
Cleared and Terminated By
RESET
(highest) 1
none
FREEZE
2
RESET
READY
3
RESET
CONFIG_COMPLETE
3
RESET
Содержание FlexRay MFR4310
Страница 1: ...FlexRay Communication freescale com Controllers MFR4310RM Rev 2 03 2008 MFR4310 Reference Manual...
Страница 2: ......
Страница 3: ...MFR4310 Reference Manual MFR4310RM Rev 2 03 2008...
Страница 6: ...MFR4310 Reference Manual Rev 2 6 Freescale Semiconductor...
Страница 12: ...MFR4310 Reference Manual Rev 2 12 Freescale Semiconductor Section Number Title Page...
Страница 24: ...MFR4310 Reference Manual Rev 2 24 Freescale Semiconductor Table Number Title Page...
Страница 28: ...Introduction MFR4310 Reference Manual Rev 2 28 Freescale Semiconductor...
Страница 58: ...Device Overview MFR4310 Reference Manual Rev 2 58 Freescale Semiconductor...
Страница 222: ...Dual Output Voltage Regulator VREG3V3V2 MFR4310 Reference Manual Rev 2 222 Freescale Semiconductor...
Страница 234: ...Clocks and Reset Generator CRG MFR4310 Reference Manual Rev 2 234 Freescale Semiconductor...
Страница 260: ...Package Information MFR4310 Reference Manual Rev 2 260 Freescale Semiconductor...
Страница 267: ......