![Free Hot Water Freedom 5002 Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/free-hot-water/freedom-5002/freedom-5002_installation-operation-and-maintenance-manual_2329367050.webp)
Page 50
Free
Hot
Water Label Set
Instructions:
The following labels must be attached to the relevant valves in the system in order for it to be
considered OG-300 compliant. This page should be laminated, each label cut from it, punched in the margin at the
right hand side and affixed to the appropriate valve with a wire tie, plastic ties are inappropriate due to high
operating temperatures. Failure to affix these labels will void the SRCC OG-300 system certification (Refer to page
33 Item C and page 35 Item D for placement)
Pump Station fill/drain valves (Warning Hot) (Refer to page 33 Item C and page 35 Item D for placement)
Pump Station fill/drain valves (Warning Hot) (Refer to page 33 Item C and page 35 Item D for placement)
Collector Array Isolation RETURN Valve (Refer to page 33 Item A and page 35 Item B for placement)
Collector Array Isolation SUPPLY Valve (Refer to page 35 Item A for placement and page 12, 13)
Cold water supply line isolation ball valve (Refer to page 12, 13)
Isolation Valve 15A Normally Open (Refer to page 12, 13)
Isolation Valve 15C Normally Open (Refer to page 12, 13)
Isolation Valve 1B Normally Closed (Refer to page 12, 13)
Pump Station fill/drain valves (Warning Hot)
SAFE-T-THERM
®
Propylene Glycol Heat Transfer Fluid - AWWA Class II
Please consult your installation manual for specific freeze tolerance
information. Valve is closed after filling. Be extremely careful when
draining this fluid. It may be discharged at a very high temperature
and/or pressure. Single Wall Heat Exchanger - NO other fluid shall
be used that would change the original classification of the
system.Unauthorized alterations to this system could result in a
hazardous health condition.
Pump Station fill/drain valves (Warning Hot)
SAFE-T-THERM
®
Propylene Glycol Heat Transfer Fluid - AWWA Class II
Please consult your installation manual for specific freeze tolerance
information. Valve is closed after filling. Be extremely careful when
draining this fluid. It may be discharged at a very high temperature
and/or pressure. Single Wall Heat Exchanger - NO other fluid shall
be used that would change the original classification of the
system.Unauthorized alterations to this system could result in a
hazardous health condition.
Содержание Freedom 5002
Страница 3: ...Page 3...
Страница 4: ...Page 4 Attention Do not lift the collectors by the connections and or the screw threads...
Страница 10: ...Page 10...
Страница 12: ...Page 12...
Страница 13: ...Page 13...
Страница 33: ...Page 33...
Страница 57: ...Page 57 Maintenance Notes Notes...
Страница 59: ...Page 59...