Plumbing Connection of additional applications
1.
Please follow the diagrams and the notes.
2.
If you are in doubt or attempting to install an application outside the below diagrams, please contact Free
Hot Water service desk for advice.
IMPORTANT NOTE:
When using copper pipes, use
Teflon
or FHWM-30572200 neutral adaptor between the brass fitting and the port
thread to prevent electrolysis
Tank Sizes
79 Gallon - FHW Single Coil Solar Tank 79 gal - FHWC-STEN-079-SC
105 Gallon - FHW Single Coil Solar Tank 105 gal - FHWC-STEN-105-SC
Important Notes:
Not all valves are supplied with the water heater. The above diagram describes valves for a mains
pressure arrangement; however the tank could also be fitted to a low pressure system. Free Hot Water
tanks are equipped with a service circulation port.
Free Hot Water recommends ¾” Stainless Steel Helical Flexible Tube for connections on the roof (no
welding work needed and pre-UV R6 insulated), or use standard ¾” copper pipe. All outdoor pipe is to
have UV protected insulation. Final 5 feet of cold water piping is insulated to R-2.6