Connect collectors with each other (if installing more than one collector) and with storage tank, using
flex hose or copper pipe and compression fittings.
Note: * Tighten compression fittings gently by hand and then 1.25 turns with a wrench. Avoid over-
tightening as this can damage the flex hose or copper tubing.
22.
Cap unused collector connections with cap.
23.
If not already labeled, install hot and cold water in and out labels to collector and storage tank.
24.
Test system, checking for any leaks and for performance. Collector mounting must be capable of
maintaining tilt and azimuth.
Fig 1.91