COMMUNICATIONS
Modbus RTU Communication
45
438
RW
N
Undr Vlt Enable
0 - Off
1 - Fault and Alarm (default)
2 - Alarm Only
Undervoltage Protection Enable
439
RW
N
Undr Vlt Level
75 to 99; default = 90
Undervoltage Level Percentage
440
RW
N
Undr Vlt Delay
1 to 120; default = 10
Undervoltage Delay Time in seconds
441
RW
N
Undr Vlt Reset
0 - Manual
1 - Automatic (default)
Undervoltage Reset Method
442
RW
N
Undr Vlt Retry
1 to 10; default = 3
Undervoltage Automatic Reset Allowed Attempts
443
RW
N
Undr Vlt Rst Dly
1 to 43,200; default = 900
Undervoltage Automatic Reset Delay in seconds
444
RW
N
Unbl Vlt Enable
0 - Off (default)
1 - Fault and Alarm
2 - Alarm Only
Unbalanced Voltage Protection Enable
445
RW
N
Unbl Vlt Level
1 to 25; default = 1
Unbalanced Voltage Level Percentage
446
RW
N
Unbl Vlt Delay
1 to 120; default = 10
Unbalanced Voltage Delay Time in seconds
447
RW
N
Unbl Vlt Reset
0 - Manual
1 - Automatic (default)
Unbalanced Voltage Reset Method
448
RW
N
Unbl Vlt Retry
1 to 10; default = 3
Unbalanced Voltage Automatic Reset Allowed Attempts
449
RW
N
Unbl Vlt Rst Dly
1 to 43,200; default = 900
Unbalanced Voltage Automatic Reset Delay in seconds
450
RW
N
Rev Phase Enable 0 - Off
1 - Fault and Alarm (default)
2 - Alarm Only
Phase Reversal Protection Enable
451
RW
N
Phase Order
0 - A B C (default)
1 - A C B
Phase Order
452
RW
N
Underpower
Enable
0 - Off
1 - Fault and Alarm (default)
2 - Alarm Only
Under Power Protection Enable
453
RW
N
Underpower Level 1 to 99; default = 50/65
Under Power Level Percentage
SMS default = 65
Reduced Voltage SMS default = 50
454
RW
N
Underpower Delay 1 to 120; default = 2/3
Under Power Delay Time in seconds
SMS default = 3
Reduced Voltage SMS default = 2
455
RW
N
Underpower Reset 0 - Manual
1 - Automatic
2- Well Recovery (Pump
only)
Under Power Reset Method
456
RW
N
Underpower Retry 1 to 10; default = 3
Under Power Automatic Reset Attempts
457
RW
N
Underpower Rst
Dly
1 to 43,200; default = 900
Under Power Reset Delay in seconds
458
RW
N
Ovr Pwr Enable
0 - Off
1 - Fault and Alarm (default)
2 - Alarm Only
Over Power Protection Enable
459
RW
N
Ovr Pwr Level
101 to 200; default = 125
Over Power Level Percentage
460
RW
N
Ovr Pwr Delay
1 to 120; default = 3
Over Power Delay Time in seconds
461
RW
N
Ovr Pwr Reset
0 - Manual
1 - Automatic (default)
Over Power Reset Method
462
RW
N
Ovr Pwr Retry
1 to 10; default = 3
Under Power Automatic Reset Attempts
463
RW
N
Ovr Pwr Rst Dly
1 to 43,200; default = 900
Under Power Reset Delay in seconds
Mod
Bus R/W
RC
Address Name
Choices/Range
Description
Содержание SUBMONITOR CONNECT MT1111
Страница 1: ...franklinwater com SUBMONITORCONNECT Installation and Operation Manual ...
Страница 60: ...SPECIFICATIONS Wiring Diagrams for Panels 60 Standard SMS Panel Using Current Transformers 200 480VAC MT1311 ...
Страница 61: ...SPECIFICATIONS Wiring Diagrams for Panels 61 Standard SMS Panel Using Current Transformers 600VAC MT1311 ...
Страница 62: ...SPECIFICATIONS Wiring Diagrams for Panels 62 Standard SMS Panel with PWM Contactor Output MT2211 ...
Страница 63: ...SPECIFICATIONS Wiring Diagrams for Panels 63 Reduced Voltage SMS Panel with Relay Contactor Output MT1311 ...
Страница 66: ...SPECIFICATIONS Wiring Diagrams for Panels 66 Reduced Voltage SMS Panel with PWM Contactor Output MT2211 ...
Страница 72: ...800 348 2420 franklinwater com For technical assistance please contact Form 250001701 Rev 002 06 19 ...
Страница 73: ...ESPAÑOL ES franklinagua com SUBMONITORCONNECT Manual de instalación y funcionamiento ...
Страница 142: ...ESPECIFICACIONES Diagramas de cableado para paneles 70 Panel SMS estándar con salida de contactor PWM MT2211 ...
Страница 146: ...ESPECIFICACIONES Diagramas de cableado para paneles 74 Panel SMS de voltaje reducido con salida de contactor PWM MT2211 ...
Страница 152: ...800 348 2420 franklinagua com Para la ayuda técnica por favor póngase en contacto Form 250001701 Rev 002 06 19 ...
Страница 153: ...franklinwater com FRANÇAIS FR SUBMONITORCONNECT Manuel d installation et d utilisation ...
Страница 220: ...SPÉCIFICATIONS Diagrammes de câblage pour les panneaux 68 Panneau SMS standard avec sortie de contacteur PWM MT2211 ...
Страница 229: ...NOTES 77 NOTES ...
Страница 230: ...NOTES 78 NOTES ...
Страница 232: ...800 348 2420 franklinwater com Pour l aide technique entrez s il vous plaît en contact Form 250001701 Rév 002 06 19 ...