F3Dn Service Manual Motor Test / Section 2.5
For Technical Support, Call 800-537-2653. Copyright
2006 Franke, Inc. All rights reserved.
2.5 Motor Test Procedure Continued:
Specific
base-level
Diagnostic Values are logged at Plant and
posted on back of unit above Main Control Boards.
Ø
To Replace Drum Rotor Motor…See
Section 2.6
Ø
To Replace Door Lift Motor…See
Section 2.7
Ø
To Replace Door [Open] Motor…
See Section 2.8
Rev. 2 10/06
Step
Action Required
Resulting Diagnostic Display
16
Press SW3 button.
[Go to next test.]
Door Motor?
//
1 = OK 3 = Nxt
[Next]
17
Press SW1 button. [=OK]
Door Trq = 0000
//
1 = Go 3 = Ex
[Exit]
18
Press SW1 button. [Activates one full
door-open & dispense cycle.]
Door Trq = 00XX
[Typically a low value] //
1 = Go 3 = Ex XXX
[Cycle count]
19
Press SW3 button [=Next].
Error Log ? 1 = OK 2 = Nxt 3 = Ext
20
Press SW1 button. [=OK]
FTO=000
[Fill Time Out – the number of
occurrences]
DTQ=000
[Drum torque
faults – number of occurrences] //
2 = Clr
3 = Rtn
[Return]
21
Press SW3 button [=Clear]
Resets FTO and DTQ counters to “
000
”
22
Press SW3 button [=Rtn]
Show Cal ?
//
1 = OK 2 = Nxt 3 = Ext
23
Press SW1 button [=OK]
Z = 00000 C= 00024 P = 02145
//
1 = OK
3 = Ext
[Values should be close to those
on sticker. See photo below.]
24
Press SW3 button [=OK]
Motor Tests ? 1 = OK 2 = Nxt 3 = Ext
25
Press SW3 button [=Exit]
Shut Lift /Stby
[Standby]
Ø