F3Dn Service Manual Control Panel Guide / Section 1.6
For Technical Support, Call 800-537-2653. Copyright
2006 Franke, Inc. All rights reserved.
Control Panel Function Guide:
-1-
-2-
-3-
-4-
-5-
-6-
Each lane overlay has the following touch-pad controls and LED displays:
1.
LANE POWER
– Turns individual lane on and off.
Press and Hold
to activate. Press
again to
change to AUTO or MANUAL. Do NOT turn lane ON until after hopper is filled with fries.
2.
PRESS FOR MANUAL DISPENSE
– Press touch pad to dispense a single load of fries. LANE
POWER must be in MANUAL mode, the lights above MANUAL DISPENSE button illuminated and
an empty fries basket in load position. (
Note:
In
AUTO
Mode, a load of fries is dispensed
automatically, if basket is present and activates basket-present sensor.)
3.
LOAD READY
– Indicates that lane is ready to dispense a load of fries.
4.
LOAD SIZE
– Indicates size of load of fries to be dispensed. Can only be changed when LOAD
READY lights are illuminated. The default is LARGE (Load Size). Pressing LOAD SIZE touch-pad
cycles from: LARGE to SMALL, to MEDIUM, then back to LARGE.
5.
RESET LANE
– A fault condition has occurred.
•
Flashing Lights
– Time out error. Hopper is either out of fries or a bridge has formed
preventing fries from feeding. Correct condition and press RESET LANE button to resume
normal operation.
•
Lights ON
– Failure to tare error. Most likely an assembly issue. Disassemble and
reassemble lane per Operating Manual or Quick Reference Card instructions. Make sure all
stray fries are cleaned out. Then press RESET LANE button to resume normal operation.
6.
LOW PRODUCT
– Fry level in hopper is low and hopper should be refilled. Approximately 1 bag
of fries remains. Unit will continue to dispense fries.
Rev.1 6/06