PostBase Vision
154
18.10
Sealer
(optional)
18.10.1 Cleaning
The sealer should be cleaned once a month to remove glue residues.
• Separate the sealer from the franking
machine:
Slightly lift the franking machine on the left
side and pull the sealer away to the left.
• Swing up the rocker with the moistening
felt.
• Thoroughly rinse absorption and
moistening felts under running water.
• Wipe the housing with a damp cloth. You
can also use a commercially available
dishwashing detergent.
• Fill with sealing fluid (see page 155).
• Dry the sealer.
• Connect the sealer to the franking machine
(see page 23).
Rocker with
moistening felt
Moistening felt
Absorption
felt