background image

 

 

21 

2.5.12. 

Viewing more than one Data Set on the Graph 

MicroLab Lite lets you view more than one data set in Graph and Table view at the same 
time, allowing you to compare the data from several data sets side by side. 

Note:

  To  use  this  feature  the  data  sets  must  have  been  recorded  using  the  same 

sampling rate e.g. every 1 minute 
 
There are two modes when using the Multi-graph feature: 

Standard mode 

The time scale of all data on the graph is the same. The time and date of data recorded 
in the first data set included on the graph is used.  
For example, if you have a graph whose data was recorded starting 10:00AM on August 
11, then all additional data added to the graph will be displayed with the same recording 
date. 
 
The  MicroLab  Lite  data  table  below  shows  all  data  in  the  graph  having  the  same  time 
scale: 

 

Figure 7: MicroLite data table 

Plot sync mode 

To  display  data  on  the  graph  using  the  data’s  actual  time  scale  i.e.  the  time  and  date 
when  the  data  was  actually  recorded,  use  the 

Plot  sync

  feature. This  will  also  shift  all 

data in the data table accordingly.  
Once  you’ve  added  the  data  to  the  graph,  on  the 

Graph 

menu

select

  Plot  sync

  to 

enable the feature. To return to Standard mode, unselect 

Plot sync

.  

 

Note:

 The time scale of all data is rounded to the same resolution as the time scale of 

the original data on the graph.  

2.6. 

Analysis Tools 

2.6.1. 

Setting the Analysis Tools Parameters 

1.  Click 

Analysis

  on  the  menu  bar,  then  click 

Set 

Functions’  Parameters

  to  open  a 

dialog box: 

www.esis.com.au

Ph  02 9481 7420

Fax 02 9481 7267

[email protected]

Содержание MicroLab Lite

Страница 1: ...MicroLite MicroLab Lite User Guide Fifth Edition April 2011 fourtec Fourier Technologies www esis com au Ph 02 9481 7420 Fax 02 9481 7267 esis enq esis com au...

Страница 2: ...equirements 8 2 2 2 Installation Procedure 8 2 3 Getting Started 10 2 3 1 Setting up the MicroLite 10 2 3 2 Completing the Setup 12 2 3 3 Starting Data Recording 12 2 3 4 Stopping Data Recording 13 2...

Страница 3: ...cture 20 2 5 12 Viewing more than one Data Set on the Graph 21 2 6 Analysis Tools 21 2 6 1 Setting the Analysis Tools Parameters 21 2 6 2 Histogram 22 2 6 3 Pasteurization 22 2 6 4 Statistics 23 2 7 T...

Страница 4: ...ore Chapter 1 of this user guide details the operational procedures for MicroLite as a standalone device Chapter 2 provides instruction on how to work with the MicroLite software MicroLab Lite Contact...

Страница 5: ...the placeholder on the MicroLite packaging Read more about the purpose of this magnet in section 1 6 3 on page 6 In order to save battery life MicroLite is shipped in Stop Mode This means that before...

Страница 6: ...ou will be looking at the actual temperature recorded at that very moment MicroLite Alarm MicroLite displays an alarm notification whenever any alarm level is exceeded AL L The temperature reading is...

Страница 7: ...s idle and is not recording When pressing Stop in the MicroLab Lite software the logger LCD immediately ceases to record data instead displaying STOP and scrolling through the alarm durations if alarm...

Страница 8: ...he USB port the LCD will display STOP If the logger had recorded an alarm during the previous data logging session then the LCD will also scroll through the alarm durations 1 6 The MicroLite Battery T...

Страница 9: ...te settings These can be restored the next time you Setup the logger using MicroLab Lite After replacing the battery the MicroLite LCD will display PUSH indicating it is in Push to Run mode Once you c...

Страница 10: ...side the small holder next to the battery compartment for two seconds and then remove the magnet The MicroLite LCD will immediately move to Run mode and live temperature data will be displayed Magnet...

Страница 11: ...To work with MicroLab Lite your system should be configured with the following Software Windows 2000 Windows XP Server 2003 and Vista Internet Explorer 5 0 or higher Hardware Pentium 200 MHz or higher...

Страница 12: ...process The default installation location is C SiLabs 5 When the following dialog pops up click Install 6 The installation of the driver could take up to one minute or more depending on the system www...

Страница 13: ...ally detect it Troubleshooting When connected to the PC USB port the MicroLite was not detected by the software Ensure that the USB driver was installed properly If it is then the MicroLite LED will l...

Страница 14: ...option you want Celsius or Fahrenheit Temperature alarm Type in the desired Low and High alarm levels If the MicroLite records a reading that exceeds either of these levels the MicroLite s LCD will d...

Страница 15: ...et to close the reed relay on the MicroLite s circuit board thereby causing the logger to start recording data This is convenient for when you wish to start recording data soon but not immediately fol...

Страница 16: ...tion the calibration procedure is protected by a password The default password is 1234 To change the password 1 Click Logger on the main menu and then click Calibration 2 Click Change Password to open...

Страница 17: ...munication Setup dialog box The selected COM ports are available for communication 1 Click Try to connect to establish communication 2 Click Work offline to work with saved files and no logger detecti...

Страница 18: ...ave all the data sets select Save all from the File menu Note If you want to remove unwanted data before saving apply the Crop tool refer to page 19 2 4 MicroLab Lite Basics 2 4 1 Opening Files 1 Clic...

Страница 19: ...o keep the graph clear and simple only two Y axes can be shown on the graph simultaneously If there are three curves in the graph one of the Y axes will be hidden To make this axis visible select the...

Страница 20: ...t coordinates of the selected data recording will appear in the status bar at the bottom of the graph window To display a second cursor double click anywhere on the graph or click Second cursor on the...

Страница 21: ...ick Graph Properties on the graph toolbar 2 Check the Use default zoom check box and click OK Every file and every data recording you download will automatically open in the default zoom as long as th...

Страница 22: ...nes tab and then select the plot or axis you want to format in the Select plot drop down menu 3 From here you can format the line s color style and width as well as the markers color and style To remo...

Страница 23: ...he file and then a new Excel workbook will be opened displaying the data along with the MicroLite info including the MicroLite name serial number and alarm levels setup If Excel is not installed on th...

Страница 24: ...be displayed with the same recording date The MicroLab Lite data table below shows all data in the graph having the same time scale Figure 7 MicroLite data table Plot sync mode To display data on the...

Страница 25: ...ta sets You can modify the histogram to your needs You can set the upper limits of the first bin and the lower limit of the last bins and refine the histogram by increasing the number of bins To modif...

Страница 26: ...ow To hide the statistics click Statistics a second time 2 7 Toolbar Buttons 2 7 1 Main Upper Toolbar Open Opens saved files Save Saves the data that is currently displayed Print Opens the Print Optio...

Страница 27: ...ation to the graph Move annotation Relocates the annotation on the graph Zoom in Activates the zoom tool Pan Activates the pan tool Autoscale Returns the graph to full view Graph properties Opens the...

Страница 28: ...ductor enabling fast response time Software calibration is possible Outputs 3 digit 7 segment LCD with decimal point USB 2 0 interface Memory Capacity 8 000 samples or 16 000 samples depending on Micr...

Страница 29: ...L Graphic analysis tools such as Markers Zoom Setup windows for setting the MicroLite unit name sampling rate and alarm level Sampling rate Once every second to once every two hours MicroLite sensor c...

Страница 30: ...MICROLITE MAGNET HOLDER 7 FIGURE 4 LOGGER SETUP DIALOG BOX 11 FIGURE 5 CALIBRATION DIALOG BOX 13 FIGURE 6 COMMUNICATION SETUP DIALOG BOX 14 FIGURE 7 MICROLITE DATA TABLE 21 FIGURE 8 FUNCTIONS PARAMET...

Отзывы: