FORTEZA JSC FORTEZA FMC 24 Pro (100m, 200m, 300m)
Please visit our internet sites:
Fig. 2.5
Warning: Do not open the detector’s housing, because it may damage the device!!!
Note: Always use separated cables for the power supply circuit as the cables for the
alarm signal circuit to avoid unexpected alarms.
Note: The alarm contact loading capacity is up to 30 Vdc 0.1 A.
Note: All the electronic connections should be carried out only after power is
disconnected.
Methods of connecting the system to the main security control panel
2.3.3. In the transmitter the tamper circuit contacts (“TAMPER”) must be connected to
the control unit with a separate closed circuit.
In the receiver the tamper circuit contacts (“TAMPER”) and alarm circuit contacts can
be connected to the control unit (protection panel) in two ways: