FORTEZA JSC FORTEZA FMC 24 Pro (100m, 200m, 300m)
Please visit our internet sites:
Figure 8.1
LOGS
contain the history of statuses of each detector input (Normal, Alarm, Break,
Closed) and duty personnel actions history (changing the detector settings).
Log can be used for the detailed analysis of the events that occurred during operation.
For convenience, after switching on the detector it is recommended to set the date and time.
For that it is necessary to press TIME AND DATE SYNCRONIZATION button. Time and
date are used to generate entries in the event log.
If the detector power fails, time and date are not saved. Therefore, after each power
failure, time and date should be set again.
Maximum number of records that can be stored in the detector's memory is 1,000.
When 1,001-st event occurs, the oldest record is deleted. Thus, up to 1,000 recent event
records can be stored in the detector's memory.
It is possible to save the log into a text file. To do this, press SAVE LOGS button. The
log can be cleared by pressing CLEAR button. (
Figure 8.2)