background image

 

FORTEZA JSC                                                                          FORTEZA FMC 24 Pro (100m, 200m, 300m) 

 
 

Please visit our internet sites:                        

www.forteza.com

    or    

www.forteza.eu

                   Page 27 

 

 

Fig. 6.1 

 

6.3. Setup Method: Auto 

In most of the case ‘Auto’ mode and default sensitivity value is recommended. The 

most important is to set the proper ‘Zone length’ according to the installation site, sensitivity 
value will be set up automatically. You can send your setting to the receiver with ‘Apply’ 
button, or you can cancel your settings with ‘Cancel’ button. 

 

 

Note: If the zone length is not the real distance, there might be higher false alarm 

rate or poor sensitivity. 

 

Fig 6.2

 

Содержание FMC 24 Pro

Страница 1: ...C 24 Pro 100m 200m 300m Please visit our internet sites www forteza com or www forteza eu Page 1 Local Microwave Protective Detector Forteza FMC 24 Pro 100m 200m 300m Description Manual Service Instruction No 2020 08 15 2020 ...

Страница 2: ...nerated by breaking the individual point relay contacts Then it is transmitted on the receiver 1 1 2 The detector is intended for continuous round the clock outdoor operation at an ambient temperature 40ºC 60 С and relative humidity up to 98 at the temperature 35 С 1 1 3 When the sensor operates with the alarm complex you can control the sensor with RS 485 interface 1 2 Specifications 1 2 1 The re...

Страница 3: ...m The parameters of TAMPER button voltage 30 V maximum current consumption 0 1 A maximum Protection class IP55 The configuration and the dimensions of the detection zone are given in fig 1 1 and table 1 1 Table 1 1 Length of a sector L m 25 50 100 200 300 Detection zone width b m max 0 7 1 0 1 5 1 9 2 1 Detection zone height h m max 1 4 1 4 1 6 1 8 1 8 1 2 2 The detection zone is a volumetric part...

Страница 4: ...minimum Orange and brown wires marked NC normally closed or NO normally open and this alarm is transmitted over RS 485 interface 1 2 6 The sensor generates a fault signal at the absence of Tx signal the absence of supply voltage or at its reduction lower than 8 mV Rx or Tx failure 1 2 8 Upon the opening of Rx cover the sensor generates an alarm At the same time the contacts of the TAMPER opens too...

Страница 5: ...of the signal amplitude in Rx The signal passes through the amplifier and is compared with the thresholds value according to the algorithm If the signal change on Rx input is provoked by a person passage then Rx generates an alarm breaking actuating relay contacts The signal changes depend on height and weight of the intruder place of the sector crossing its relief and speed of the movement 1 4 3 ...

Страница 6: ...n the two vertical surfaces of the housing for mounting brackets The brackets can be mounted on the right and left side depending on the need The FMC 24 Pro comes with plug in screws that prevent housing from moisture 1 5 3 Tx construction and its bracket are the same as the Rx construction see fig 1 2 The difference is in internal elements under cover 6 are shown in fig 1 3 b six wires cables are...

Страница 7: ...FORTEZA JSC FORTEZA FMC 24 Pro 100m 200m 300m Please visit our internet sites www forteza com or www forteza eu Page 7 Fig 1 2 ...

Страница 8: ...3 Receivers control panel RX Fig 1 4 Marking RX 1 RS 485 interface switch 5 LED indication 2 Bluetooth interface switch 6 Tamper circuit 3 Bluetooth interface indication 7 Frequency band switch 1 8 4 USB connection 8 End of Line resistor of triggering circuit 9 Tamper circuit resistor 10 Alarm signal commutating scheme switch ...

Страница 9: ...the frequency channels switch are set on the transmitter and the receiver Only one of four switches can be set with the same number on the receiving and the transmitting side when the power supply is ON 1 6 2 Adjustment and control of the sensors is performed by using the controller placed on the receivers panel using Android or Windows software 1 6 3 Manual adjustment adjustment is possible witho...

Страница 10: ... case the issue of the use of the detector under these conditions is defined by the trial operation b The height of the grass should not exceed 0 3m c The height of the snow should not exceed 0 5m d The maximum incline of the sector is 45 e Single fixed objects e g posts trees without lower branches can be situated in the detection zone at the distance of 0 5 m minimum from the axis f The width of...

Страница 11: ... to 0 1 m sec middle and up to 0 4 m sec low The speed of the violator can be adjusted by connecting to the sensor using an Android device with the Forteza Soft app or using the Windows Forteza Software device program After that it is necessary to set the alarm sensitivity again For example open perimeter section high movement speed of the violator set min 0 2 m s max 10 m s standard protection se...

Страница 12: ...l objects or by wet surfaces after rain and snow may cause interference and false alarms 2 2 2 Mount the supports It is recommended to use metal or asbestos cement tube as supports of 70 90 mm diameter The height of the support above the surface of the ground is given in fig 2 3 In the places where there is a lot of snow the superstructure of the support should be 1500 mm minimum As for the suppor...

Страница 13: ...dismounting of the support 8 ground Fig 2 3 Note 1 For A size the ground should be laid after installation works 2 Dimensions are given in millimeters mm 2 2 3 Other variants of the sensor mounting for example on the fence or wall can be applied according to the protection tactics If the sensor blocks the top of the fence it is recommended to fasten the support with the fence with a solid mechanic...

Страница 14: ...2 2 4 Lay the main cables according to the project of the security system It is recommended to use multicore cables with the core screen or metal sheath The cable core section is chosen on condition that the supply voltage is not less than 9 V for every sensor unit It is not recommended to lay the main cables near heavy electromagnetic interference sources power lines antenna systems and etc and t...

Страница 15: ...ual to the fence height 100 mm 3 The dimensions and materials of the fence are not specified It is necessary to provide the fence rigidity 4 The detection zone dimensions b and h are given for the correct alignment of the sensor according to i 2 4 2 5 5 To avoid co interference between neighboring detectors you can adjust them to different operation channels don t forget to change receiver s and t...

Страница 16: ...le 2 2 RX Color Purpose Marking Blue Power supply Red Brown Normally closed contacts of actuating relay NC NC1 Orange NC2 Black Tamper button contacts Tamper1 Yellow Tamper2 White Contacts of RS 485 connection RS А Green RS В TX Color Purpose Marking Blue Power supply Red Black Tamper button contacts Tamper1 Yellow Tamper2 ...

Страница 17: ...oid unexpected alarms Note The alarm contact loading capacity is up to 30 Vdc 0 1 A Note All the electronic connections should be carried out only after power is disconnected Methods of connecting the system to the main security control panel 2 3 3 In the transmitter the tamper circuit contacts TAMPER must be connected to the control unit with a separate closed circuit In the receiver the tamper c...

Страница 18: ...e closed circuit 2nd way The actuator TAMPER relay is switched on sequentially with the contacts of the actuator relay contacts NOTE In order to use 1st way switches no 10 see figure must be switched to position 4w In order to use 2nd way switches no 10 see figure must be switched to position 2w Factory settings RTAMPER RALARM 5 6 kOhm ...

Страница 19: ...nuously which means that the power supply is correct and the transmitter is operating normally If the LED blinks in red it means that the power supply current is below the required value of 9V A rare blinking of the red LED indicates a transmitter malfunction RECEIVER After supplying power the LED will flash as many times as the set channel is set after that it will start to light in green what me...

Страница 20: ... areas of the detection zone trenches hills spaces near barriers buildings and trees which are in the detection zone If necessary change the sensitivity of the sensor Note If at the factory settings the sensor does not activate an alarm during the test run please adjust the sensitivity using the Forteza soft program 2 4 3 5 When adjustment work is finished close the covers of the receiver and tran...

Страница 21: ...connection via USB port using USB RS 485 converter When the application is initially started the connection to detector 253 broadcast address is made at the speed of 57 600 bps When necessary the communication speed via RS 485 interface and the detector s network address may be changed in the Network settings window which appears when button is pressed after connection type selection After selecti...

Страница 22: ...blishing the connection and receiving information on the detector status will begin 4 PROGRAM START UP GENERAL TAB After connecting the Android device to the detector the main window with active GENERAL tab Figure 4 1 which displays the detector parameters Before starting work it is recommended to go to the LOGS tab and synchronize the time and date unit 8 Work with Log This action is necessary fo...

Страница 23: ... Closed Noise yellow After pressing ADDITIONAL SETTINGS button Figure 4 2 it will be possible to enter the information about detector location DETECTOR LOCATION change its network address NETWORK ADDRESS output relay contact type ALARM TYPE and duration of alarm notification duration ALARM TIME as well as sound management ALARM SOUND Acceptable number of characters to enter and the number bounds a...

Страница 24: ...ches see 2 4 Zone length The currently selected operation distance for the detector It is really important to choose the proper operation distance Note It is used only in Setup Method AUTO Note If the zone length is not the real distance there might be higher false alarm rate or poor sensitivity Setup method The currently selected setup method You can choose Auto Manual SPECIAL 1 or SPECIAL 2 setu...

Страница 25: ...bookmark 5 3 Firstly you need to calibrate fine positioning the transmitter unit then the receiver unit Fig 2 13 5 4 Here you can see the received signal from the transmitter on a dynamically changing scale The maximum value of the current positioning is always signed If you are close to the maximum value of the current positioning the changing lane becomes green It means the positioning made well...

Страница 26: ...ds 5 7 Don t desalting Rx and Tx down or towards The detector keeps its operation using Calibration voltage 2 5 mV The recommended boundary values of 8 mV and 200 mV during the adjustment are recommended for the resource of the signal level to provide a long operation 6 SETTING THE THRESHOLD LIMIT VALUES USING ANDROID 6 2 After successful calibration you can come back to setup menu Here you can de...

Страница 27: ...sensitivity value is recommended The most important is to set the proper Zone length according to the installation site sensitivity value will be set up automatically You can send your setting to the receiver with Apply button or you can cancel your settings with Cancel button Note If the zone length is not the real distance there might be higher false alarm rate or poor sensitivity Fig 6 2 ...

Страница 28: ... influence on the next one Fig 6 3 6 3 2 You can change the minimum detected speed in m s Vmin the maximum detected speed in m s Vmax You can confirm your settings with Apply button Note Too big speed range has higher false alarm rate too low speed range has poor sensitivity 6 3 3 Setup method Manual In Manual setup method you can set sensitivity But in most of the case Auto mode and default sensi...

Страница 29: ...EZA JSC FORTEZA FMC 24 Pro 100m 200m 300m Please visit our internet sites www forteza com or www forteza eu Page 29 Fig 6 4 Select method Manual Fig 6 5 Sensetivity window is active zone length is deactive ...

Страница 30: ...onnect the RS 485 and close the RX cover 7 SCANNING In order to monitor electronic environment in the place where the sensors receiver is installed additionally to evaluate the influence of neighboring detectors select SCAN tab The histogram of signal levels will be displayed in the window for each of the eight frequency channels Figure 7 1 If necessary you can use the histogram scaling function Z...

Страница 31: ...ed to set the date and time For that it is necessary to press TIME AND DATE SYNCRONIZATION button Time and date are used to generate entries in the event log If the detector power fails time and date are not saved Therefore after each power failure time and date should be set again Maximum number of records that can be stored in the detector s memory is 1 000 When 1 001 st event occurs the oldest ...

Страница 32: ...ect the communication port COM Port Connection to the computer is carried out in two ways 1 Connect the RS 485 USB program converter using the cable with the plug connector included in the delivery set and connect to the receiver s port RS 485 On the main window in Communication settings tab Detector address must be selected for Jack 253 2 Connect the RS 485 program converter to communicational ne...

Страница 33: ...etection zone Simulate possible environmental influence on the detection zone movement of nearby transport or people swaying of branches or bushes due to the wind and etc Duration of the test Minimum 15 seconds Maximum until the activation of the software widow Next Possible messages after the test procedure Noise immunity is good it means that the value of the interference level threshold level r...

Страница 34: ... If the grass height is over 0 3 m the grass should be mown down 12 2 3 If the snow height changes false alarms can be generated because of the signal reduction at the Rx input In this case it is necessary to remove the snow or to change the height of Tx and Rx antennas After the height of the antennas is changed they should be aligned The thresholds should be aligned as described above 13 SAFETY ...

Страница 35: ...houses at an ambient temperature 5 С 30 С and relative humidity 85 maximum During storage the influence of hostile environment should be prevented 16 TRANSPORTATION 16 1 Packaged detectors can be transported by any transport if by plane in pressurized modules if they are transported in covered cars holds or covered bodies they can be transported at the distance up to 10 000 km The boxes should be ...

Страница 36: ...ications of the Description Manual Service Instruction No 2020 08 15 and it is considered as operable Date of issue _________202__ 1 MANUFACTURER S GUARANTEES The manufacturer guarantees the conformity of the sensor specifications to requirements of the Description Manual Service Instruction No 2020 08 15 rules specified by the Description Manual Service Instruction No 2020 08 15 Warranty period i...

Отзывы: