Using Auto-SYNC for Digital Input Connections
TIMS MVP
™
Setup and Configuration Guide 169
Let’s set the image AOI to 776x768:
Set the starting position of the image:
•
Adjust the left edge by increasing
HBS to 125
. (Horizontal Back Sync)
•
To set the end position of the image: Decrease
WIDTH
to
776
.
Notice the image width is now the size of the SMPTE circle.