4-3. Menu Setting Status Request Command
4-3-1. TIME SETUP Setting Status Request Command
This is used to request the setting status of Time Setup parameters.
Setting values are given in decimal.
[
MR
]
Request command
Byte
Parameter
Command
Description
1 M
2
Command code
R
3
Menu code
1
TIME SETUP setting
4 CR
5
End code
LF
[
RS
]
Response message
Byte
Parameter
Message
Description
1 R
2
Command code
S
3
Menu code
1
TIME SETUP setting
4–5
Split screen auto reset
time
00–60
00: OFF, 1–60 seconds
6-7
Alarm reset time
01–60
1–60 seconds
8–9
Video loss reset time
01–60
1–60 seconds
10 CR
11
End code
LF
4-3-2. AUTO SEQUENCE Setting Status Request
Command
This is used to request the setting status of Auto Sequence parameters.
[
MR
]
Request command
Byte
Parameter
Command
Description
1 M
2
Command code
R
3
Menu code
2
AUTO SEQUENCE setting
4-5 Channel
00
01–16
: Split screen
: Channel no. 1 to 16
6 CR
7
End code
LF