![FOR-A MV-1600 Скачать руководство пользователя страница 76](http://html1.mh-extra.com/html/for-a/mv-1600/mv-1600_operation-manual_2316739076.webp)
20
4-2-3. ALARM / VIDEO LOSS Setting Command
This is used to set the parameter for [ALARM/VIDEO LOSS] menu.
The “ERR” message is returned during alarm operations.
Byte
Parameter
Command
Description
1 M
2
Command code
N
3
Menu code
3
Alarm/Video loss setting
0 Trigger
input
4
Alarm input mode
1 Level
input
0 FULL
5
Alarm display mode
1 SPLIT
0 OFF
6 Alarm
ON/OFF
1 ON
0 OFF
7
Video loss ON/OFF
1 ON
8 CR
9
End code
LF
4-2-4. TITLE Setting command
This is used to set the parameter for [TITLE] menu.
The “ERR” message is returned during alarm operations.
(1) SXGA Title
Byte
Parameter
Command
Description
1 M
2
Command code
N
3 Menu
code
4
Title
setting
4 Item
code
0
SXGA
title
5-6
Title setting channel
01-16
Channel no. 1–16
6
1st character (from the left)
7 2nd
character
8 3rd
character
9 4th
character
10 5th
character
11 6th
character
12 7th
character
13
Title data
ASCII code
(
See
"Character
code table"
in the next
page
)
8th character
14 CR
15
End code
LF