![FOR-A MV-1600 Скачать руководство пользователя страница 70](http://html1.mh-extra.com/html/for-a/mv-1600/mv-1600_operation-manual_2316739070.webp)
14
3-4. Alarm Data Request Command
This is used to request the current alarm and video loss data.
Channel numbers are given in hexadecimal.
An [AA] alarm status message is returned after normal reception and processing.
[
AR
]
Request comman
Byte
Parameter
Command
Description
1 A
2
Command code
R
3 CR
4
End code
LF
[
AA
]
Response message
Byte
Parameter
Message
Description
1 A
2
Message code
A
3-6 Alarm
information
0000–FFFF
Bit no.0-15
Bit value 0: No alarm
Bit value 1: Alarm received
7-10
Video loss information
0000–000F
Bit no.0
~
3
Bit value 0: No video loss
Bit value 1: Video loss occurring
11 CR
12
End code
LF
Example 1: When alarm inputs are received at CH1, CH11 and CH16, bytes 3–6 are "8401".
Channel no.
CH
16
CH
15
CH
14
CH
13
CH
12
CH
11
CH
10
CH
9
CH
8
CH
7
CH
6
CH
5
CH
4
CH
3
CH
2
CH
1
Bit no.
15
14
13
12
11
10 9 8 7 6 5 4 3 2 1 0
Bit value
1 0 0 0 0 1 0 0 0 0 0 0 0 0 0 1
Byte value
8 4 0 1
Содержание MV-1600
Страница 1: ...MV 1600 Multi Viewer S 2nd Edition OPERATION MANUAL ...
Страница 2: ......
Страница 8: ......
Страница 52: ......
Страница 53: ...MV 1600 Multi Viewer RS 232C LAN COMMAND ...
Страница 54: ......