16
2.4. Operating data
Burner pressures must be verified after a three minute boiler operation time
KC 24
Function
Max. CH
input
(kW)
CH
output
(80-60°C)
[kW]
CH
output
(50-30°C)
[kW]
DHW
output
(kW)
Gas mains
pressure
(mbar)
Flue gas
CO
2
[%]
min
max
min
max
min
max
Methane Gas G20
23.7
6.5
22.7
7.3
24.8
7.3
28.0
20
8.8 ÷ 9.1
Propane Gas G31
23.7
6.5
22.7
7.3
24.8
7.3
28.0
37
9.8 ÷ 10.1
No. 3 chart – KC 24 model adjustment rates
Hot water supply ∆T 45°C = 8.9 l/min
Hot water supply ∆T 40°C = 10 l/min
Hot water supply ∆T 35°C = 11.5 l/min
Hot water supply ∆T 30°C = 13.4 l/min *
Hot water supply ∆T 25°C = 16.1 l/min *
*Note: mixed water to the tap
KC 32
Function
Max. CH
input
(kW)
CH
output
(80-60°C)
[kW]
CH
output
(50-30°C)
[kW]
DHW
output
(kW)
Gas mains
pressure
(mbar)
Flue gas
CO
2
[%]
min
max
min
max
min
max
Methane Gas G20
31.4
8.7
30.5
9.6
33.2
9.6
35.4
20
8.8 ÷ 9.1
Propane Gas G31
31.4
8.7
30.5
9.6
33.2
9.6
35.4
37
9.8 ÷ 10.1
No. 4 chart – KC 32 model adjustment rates
Hot water supply ∆T 45°C = 11.3 l/min
Hot water supply ∆T 40°C = 12.7 l/min
Hot water supply ∆T 35°C = 14.5 l/min
Hot water supply ∆T 30°C = 16.9 l/min *
Hot water supply ∆T 25°C = 20.3 l/min *
*Note: mixed water to the tap
KR 24
Function
Max. CH
input
(kW)
CH
output
(80-60°C)
[kW]
CH
output
(50-30°C)
[kW]
Gas mains
pressure
(mbar)
Flue gas
CO
2
[%]
min
max
min
max
Methane Gas G20
23.7
6.5
22.7
7.3
24.8
20
8.8 ÷ 9.1
Propane Gas G31
23.7
6.5
22.7
7.3
24.8
37
9.8 ÷ 10.1
No. 5 chart – KR 24 model adjustment rates
KR 32
Function
Max. CH
input
(kW)
CH
output
(80-60°C)
[kW]
CH
output
(50-30°C)
[kW]
Gas mains
pressure
(mbar)
Flue gas
CO
2
[%]
min
max
min
max
Methane Gas G20
31.4
8.7
30.5
9.6
33.2
20
8.8 ÷ 9.1
Propane Gas G31
31.4
8.7
30.5
9.6
33.2
37
9.8 ÷ 10.1
No. 6 chart – KR 32 model adjustment rates