12
2. Technical characteristics and dimensions
2.1. Technical characteristics
The boiler is equipped with a fully pre-mixed gas burner. The following models are available:
KC
: condensing boiler with sealed chamber and forced draught, supplying CH water and instant DHW;
KR
: condensing boiler with sealed chamber and forced draught, supplying CH water;
Both models are available in the following heat outputs:
KC 24 and KR 24 = 23.7 kW.
KC 32 and KR 32 = 31.4 kW.
Both models are equipped with electronic ignition and ionization flame sensing device.
The boilers meet local applicable Directives enforced in the country of destination, which is stated on their data plate.
Boiler installation in a different country from specified may endanger people, animals and objects.
The main technical characteristics of the boilers are listed below:
Manufacturing characteristics
- IPX4D electrically protected control panel
- Integrated, modulating electronic safety board
- Electronic ignition via separated igniter and ionization flame detection
- Stainless steel, fully pre-mixed burner
- Mono-thermal, high efficiency, composite and stainless steel heat exchanger with air purging device
- Twin shutter, modulating gas valve with constant air/gas ratio
- Modulating, electronically managed flue gas discharge fan
- Three-speed pump with air purging device
- Safety flow-switch, preventing operation with low water pressure in the CH system
- CH temperature probe (KC and KR) and DHW (KC)
- Safety limit thermostat
- Flue gas thermostats
- Integrated, automatic by-pass
- 10 liter expansion vessel
- System loading and draining taps
- Stainless steel plate DHW heat exchanger (KC)
- Motorized deviating valve (KC)
- DHW priority flow switch (KC)
- DHW flow limiting device; 13 liter/min (KC 24), 16 liter/min (KC 32)
User interface
- Boiler mode selector: OFF, RESET, WINTER, SUMMER, ANTI-FROST
- CH temperature adjusting switch: 20/78°C (standard range), or 20/45°C (reduced range)
- DHW temperature adjusting switch (KC): 35/57°C.
- Led displayed CH water temperature
- CH water pressure gauge
- Light emitting diodes indicating:
• power main supply connection;
• flame detection;
• burner shut-down due to flame extinguishing;
• burner shut-down due to overheating;
• burner shut-down due to flue gas pressure switch intervention;
• burner shut-down due to inadequate CH water circulation;
• burner shut-down due to fan malfunction;
• malfunction of temperature probes;
• remote control faulty connection.