Failures and warnings
177
12.1.8
Heating
If the heating does not work properly, the reasons for it may be
the following:
> In
on?
press
. Check whether the displayed temperature
increases.
> If the temperature increases, in
delete failure?
press
.
Exclusively for service personnel:
•
The heating element is defective.
> Check the heating element for continuity.
•
The temperature sensor is defective.
•
There is no voltage on the heating.
> Check the on-site fuses, if necessary.
•
The safety temperature limiter is triggered. To reactivate it,
proceed as follows:
failure
heating
heating
on?
boiler: xx.x
o
C
delete failure?
1. In
delete failure?
press
.
2. Pull the mains plug. For those devices with
fix power connection, switch the main
switch off and be sure the device is free of
voltage before getting close to live parts.
3. Open the right lateral door of the automatic
feeder. Remove the metal covering.
4. Push the Reset-button to reset the safety
temperature limiter.
Содержание TAK5-CH1-25
Страница 38: ...38 Operation ...
Страница 54: ...54 Start up ...
Страница 70: ...70 Setup ...
Страница 84: ...84 Device data ...
Страница 90: ...90 Calibration ...
Страница 150: ...150 Cleaning ...
Страница 170: ...170 Animal control ...
Страница 192: ...192 Failures and warnings ...
Страница 196: ...196 Care and maintenance plan Routine tasks ...
Страница 215: ......
Страница 218: ...218 Annex 16 3 5 Template for individual feeding plan ...
Страница 219: ...Annex 219 16 4 Basic principle of interval feeding ...
Страница 222: ...222 Annex ...