176
Failures and warnings
es
calibr. water bo.
and calibr. water HE
are displayed
again
8. Calibrate both liquid feed components.
9. Move to the default automatic mode.
12.1.7
Mixer emptying
If the cleaning water cannot be drained off the mixer because the
drain is e.g. clogged, the failure message on the right will be dis-
played. Feeding will be broken off until the failure has been
removed.
> Check all feed-supplying components leading from the mixer
to the mixer draining valve or from the mixer to the teat for
clogging and remove potential obstructions.
> Check the feeding pump. In
feed. pump: start?
press
.
> Check the mixer draining valve (if available). In
mixer drain:
open?
press
.
> Check the bar electrode.
> In
water bo.: start?
press
to fill the mixer with some wa-
ter.
> In
mixer: drain?
press
.
> As soon as the failure has been removed, confirm
delete fail-
ure?
with
.
failure
mixer: empty?
mixer emtying
feed. pump: start?
mixer drain: open?
water bo.: start?
Warning
: Before recommissioning the automatic feeder
it is imperative to remove all detergent residues in order
not to put animals’ health at risk.
Caution
: It is imperative not to extend the hose that
leads from the mixer draining valve to the drain!
Содержание TAK5-CH1-25
Страница 38: ...38 Operation ...
Страница 54: ...54 Start up ...
Страница 70: ...70 Setup ...
Страница 84: ...84 Device data ...
Страница 90: ...90 Calibration ...
Страница 150: ...150 Cleaning ...
Страница 170: ...170 Animal control ...
Страница 192: ...192 Failures and warnings ...
Страница 196: ...196 Care and maintenance plan Routine tasks ...
Страница 215: ......
Страница 218: ...218 Annex 16 3 5 Template for individual feeding plan ...
Страница 219: ...Annex 219 16 4 Basic principle of interval feeding ...
Страница 222: ...222 Annex ...