Operating Manual EMGZ480
57
13.2
Object 7130: Feedback value
This object contains the feedback value of the amplifier. The decimal point depends on
the CAN-BUS object 2003
Force of sensor.
The gain is calculated and stored in the object 2002h
Gain
and on the CAN-BUS object
2004h Unit of force sensor).
Fnom
≥
1000
Digits after decimal point: 0
Fnom < 1000 und Fnom
≥
100
Digits after decimal point: 1
Fnom < 100 und Fnom
≥
10
Digits after decimal point: 2
Fnom < 10
Digits after decimal point: 3
Object description:
Index 7130
Name Feedback
value
Object Code
ARRAY
Data Type
Integer 16
Category Mandatory
Input description:
Sub-Index 0
Description
Number of entries
Data type
Unsigned 8
Access ro
PDO Mapping
No
Value Range
01h
Default Value
No
Sub-Index 1
Description Feedback
value
Data type
Integer 16
Access ro
PDO Mapping
PDO 0
Value Range
0 … 32767 (can also contain a negative value, if the offset was
badly set)
Default Value
No