12.4
Object 2083: System Parameter Cycle time PDO
Cycle time PDO
Use:
The parameter determines the cycle time (frequency) of the PDO
transmission in the CAN-BUS interface. If this parameter is changed
the electronic unit must be reset (power off – on).
Range:
0:50, 1:100, 2:200, 3:500
Default:
100
CAN Object:
2083h
Unit:
[ms]
Object description:
Index 2083
Name
System Parameter Cycle time PDO
Object Code
ARRAY
Data Type
Integer 16
Category Mandatory
Input description:
Sub-Index 0
Description
Number of entries
Data type
Unsigned 8
Access ro
PDO Mapping
No
Value Range
1 .. 07h
Default Value
No
Sub-Index 1
Description Parameter
value
Data type
Integer 16
Access rw
PDO Mapping
No
Value Range
0: 50, 1: 100, 2: 200, 3: 500
Default Value
1: 100
Sub-Index 2
Description Parameter
name
Data type
Visible String
Access ro
PDO Mapping
No
Value Range
String
Default Value
Time slice PDO