Operating Manual EMGZ480
47
11.12
Object 2052: Parameter Calibration
Calibration
Use:
The CAN-BUS Object 2052
Calibration
determines the gain of the
feedback value. The material tension is simulated with a known weight.
This value can then be entered in [N] or [lbs]. The gain is calculated
and stored in the object 2002
Gain
. If 0 is entered, no gain value will
be calculated.
The decimal point depends on the CAN-BUS object 2003
Force of
sensor.
Fnom
≥
1000
Digits after decimal point: 0
Fnom < 1000 und Fnom
≥
100
Digits after decimal point: 1
Fnom < 100 und Fnom
≥
10
Digits after decimal point: 2
Fnom < 10
Digits after decimal point: 3
Range:
0
to
9999
Default:
0
CAN Object:
2052h
Object description:
Index 2052
Name Parameter
Calibration
Object Code
ARRAY
Data Type
Integer 16
Category Mandatory
Input description:
Sub-Index 0
Description
Number of entries
Data type
Unsigned 8
Access ro
PDO Mapping
No
Value Range
01h
Default Value
No
Sub-Index 1
Description Calibration
Data type
Integer 16
Access wo
PDO Mapping
No
Value Range
0 … 999999
Default Value
0