9.3
Description of the System Parameters
The system parameters can be read or written with the CAN-BUS Objects
Language
Use:
This parameter determines the display language on the CAN-Master
(e.g. PC or PLC)
Range:
English,
German
Default:
English
CAN Object:
2080h
Measuring system
Use:
This parameter indicates the measuring system that will be displayed. If
it is set to
metric
, all force values are shown in [N, cN, kN]. If it is set
to
US standard
, all force values are shown in [lb, clb, klb].
Range:
Metric, US standard
Default:
Metric
CAN Object:
2081h
Baudrate
Use:
This parameter sets the speed of the CAN-BUS interface. If this
parameter is changed the electronic unit must be reset (power off – on).
Range:
50, 100, 125, 250
Default:
250
CAN Object:
2082h
Unit:
[kBit]
Cycle time PDO
Use:
The parameter determines the cycle time (frequency) of the PDO
transmission in the CAN-BUS interface. If this parameter is changed
the electronic unit must be reset (power off – on).
Range:
50, 100, 200, 500
Default:
100
CAN Object:
2083h
Unit:
[ms]