Operating Manual EMGZ480
34
Sub-Index 7
Description
Parameter default value
Data type
Integer 16
Access ro
PDO Mapping
No
Value Range
Constant
Default Value
0 -> N
11.5
Object 2005: Parameter Lowpass Filter
Lowpass Filter
Use:
The electronic unit contains a low-pass filter to prevent noise from
interfere with the output signal. This parameter determines the cut off
frequency of the filter. The lower the cut off frequency, the more
sluggish the signal on the output terminals will be. Due to this filter, the
output signal will be much more stable irrespective of the fluctuations
of the force value.
Range:
0.1
to
200.0
Default:
50.0
Increment:
0.1
Unit:
[Hz]
CAN Object:
2005h
Object description:
Index 2005
Name
Parameter Low Filter
Object Code
ARRAY
Data Type
Integer 16
Category Mandatory
Input description:
Sub-Index 0
Description
Number of entries
Data type
Unsigned 8
Access ro
PDO Mapping
No
Value Range
1 .. 07h
Default Value
No