Operating Manual EMGZ480
38
11.7
Object 2007: Parameter Limit value 1
Limit value 1
Use:
CAN-BUS Object 6508.1 „
Limit value 1
“ is activated, if the defined
threshold value is over- or under-run (irrespective of the parameter
Limit value 1
min or max
). This threshold value can be set with this
CAN-BUS Object. If the parameter is set to 0, the limit value
monitoring is deactivated.
Range:
A force value can be entered. The decimal point is dependent from the
CAN-BUS Object 2003h (
Force of sensor
) and the unit from the CAN-
BUS Object 2004h (
Unit of force
).
Default:
0
Unit:
[N, kN, cN] or
[lb,
klb,
clb]
CAN Object:
2007h
Object description:
Index 2007
Name
Parameter Limit value 1
Object Code
ARRAY
Data Type
Integer 16
Category Mandatory
Input description:
Sub-Index 0
Description
Number of entries
Data type
Unsigned 8
Access Ro
PDO Mapping
No
Value Range
1 .. 07h
Default Value
No
Sub-Index 1
Description Parameter
value
Data type
Integer 16
Access rw
PDO Mapping
No
Value Range
0 .. 9999
Default Value
0
Sub-Index 2
Description Parameter
name
Data type
Visible String
Access ro
PDO Mapping
No
Value Range
String