Operating Manual EMGZ421
30
12
Technical data EMGZ421
Connection of force sensors
2 force sensors of 350
Ω
Excitation of sensors
4VDC
Input signal voltage
0...7.2mV (max. 9.92mV)
Resolution A/D converter
±4096 Digit (13 Bit)
Measuring error
<0.05% FS
Cycle time
4ms
Operation
4 keys, 4 LED’s, LCD display 2x16 characters
Analogue output 1 (Feedback A–B)
±10V (12 Bit)
Analogue output 2 (Feedback A+B)
0...10V (12 Bit)
Analogue output 3 (Feedback A)
0...5V (8 Bit)
Analogue output 4 (Feedback B)
0...5V (8 Bit)
Digital output 1 (Limit value min.A+B) Open collector, galvanic separated
Digital output 2 (Limit value max.A+B) Open collector, galvanic separated
Digital output 3 (|A–B| > limit)
Open collector, galvanic separated
Digital output 4 (Error)
Open collector, galvanic separated
Digital input 1 (Gain switching A)
24VDC galvanic separated
Digital input 2 (Gain switching B)
24VDC galvanic separated
Digital input 3 (Find offset A)
24VDC galvanic separated
Digital input 4 (Find offset B)
24VDC galvanic separated
Interface RS232
standard
Interface RS485 galvanic separated
Option
Interface CAN-Bus
Option
Power supply
24VDC (18...36VDC) 0.15A
(EMGZ421.E: 230VAC, 110VAC or 24VDC)
Main connector
DIN41612 type F b+d+z
Temperature range
0...50°C [32...122°F]
Weight
0.22kg [.5 lbs]