Operating Manual EMGZ421
17
9.3
Read parameter
command answer
purpose
RP01<CR>
XXXXX<CR>
Offset channel A
RP02<CR>
X.XXX<CR>
Gain channel A
RP03<CR>
XXXXX<CR>
Offset channel B
RP04<CR>
X.XXX<CR>
Gain channel B
RP05<CR>
X.XXX<CR>
Gain1 channel A
RP06<CR>
X.XXX<CR>
Gain1 channel B
RP07<CR>
XXXX<CR>
Nominal force sensor A
RP08<CR>
XXXX<CR>
Nominal force sensor B
RP09<CR>
X<CR>
Unit of force
RP10<CR>
X.X<CR>
Sensitivity sensor A
RP11<CR>
X.X<CR>
Sensitivity sensor B
RP13<CR>
XXXXX<CR>
Min. limit value A+B
RP14<CR>
XXXXX<CR>
Max. limit value A+B
RP15<CR>
XXXXX<CR>
|A–B| > limit
RP18<CR> XX.X<CR>
Lowpass
display
RP19<CR>
XXX.X<CR>
Lowpass output 1 (A–B)
RP20<CR>
XXX.X<CR>
Lowpass output 2 (A+B)
RP21<CR>
XXX.X<CR>
Lowpass output 3 (A)
RP22<CR>
XXX.X<CR>
Lowpass output 4 (B)
RP23<CR>
XX.XX<CR>
Scale output 1 (A–B)
RP24<CR>
XX.XX<CR>
Scale output 2 (A+B)
RP25<CR>
XX.XX<CR>
Scale output 3 (A)
RP26<CR>
XX.XX<CR>
Scale output 4 (B)
RP28<CR> X<CR>
Language
RP29<CR>
X<CR>
Config. of key
RP39<CR> XXX<CR>
Identifier
RP40<CR>
X<CR>
Baud rate RS232
RP41<CR>
X<CR>
7 or 8 data bit
RP42<CR>
X<CR>
1 or 2 stop bit
RP43<CR>
X<CR>
Parity bit RS232
All parameter numbers and input ranges refer to the parameter list.