Operating Manual EMGZ421
21
10.3
Description of the parameters
The parameter changing mode will be activated by pressing the
↵
key for 3 seconds.
Generally, the parameters are settable using the keys as follows:
choose
switch the selections or increase / decrease numeric values
change the decimal (while inputting a numeric value)
enter
Find offset A
Use:
The actual force value will be saved by pressing the
↵
key for 3
seconds. This is used to compensate the weigth of the material and the
roller. The determined value will be shown for 2 seconds and then
stored under parameter
Offset channel A.
The offset may be determinded also by activating the digital input
Find offset A
(terminal b6 resp. 25) for at least 100ms. This procedure
is equal to executing the parameter function
Find offset A
.
Calibration A
Use:
In this parameter, using the
↑
↓
keys you can input the force value
referring to half of the calibration load you applied to the sensor (force
feedback value). The processor then calculates the actual gain value
and stores it under parameter
Gain channel A.
Notice: The input can be aborted with the
←
key. In this case the
previously saved value remains.
Range:
1
to
9999
Default:
1000
Increment:
1
Unit:
[N,kN]
Find offset B
Use:
The actual force value will be saved by pressing the
↵
key for 3
seconds. This is used to compensate the weigth of the material and the
roller. The determined value will be shown for 2 seconds and then
stored under parameter
Offset channel B.
The offset may be determinded also by activating the digital input
Find offset B
(terminal b8 resp. 26) for at least 100ms. This procedure
is equal to executing the parameter function
Find offset B
.
↵
↑
↓
←
↵