Operating Manual Web Guide Controller BKS309
23.07.2019
33
Purpose:
This parameter determines the guiding orientation of the controller.
Usually turn stepper motors clockwise. This setting changes the
turning direction of the motor. There are two other possibilities to
change the guiding direction:
a) Changing the electrical polarization of the stepper motor
b) Mounting the actuator in the opposite direction
The user can choose between two settings
Setting:
[Standard]
Purpose:
[
Standard]
is chosen when standard motors and standard frames are
used.
Setting:
[Invers]
Purpose:
[
Invers] is chosen when motors are used that turn anticlockwise. If a
FMS actuator of the type winderGLIDE is used, the controller sets the
drive direction automatically.
Actuator Type [winderGL]
Purpose:
This parameter determines the used actuator type. The product name
of FMS actuators is winderGLIDE.
The user can choose between three types.
Type:
[D.3.125] or [D.4.125] or [D.6.125]
Purpose:
If type [D.3.125] or [D.4.125] or [D.6.125] the max. stroke is set to
125mm (4.92in).
Type:
[D.3.200] or [D.4.200] or [D.6.200] or [D.7.200]
Purpose:
If type [D.3.200] or [D.4.200] or [D.6.200] or [D.7.200] the max. stroke
is set to 200mm (7.87in).
Type:
[D.3.300] or [D.4.300] or [D.6.300] or [D.7.300]
Purpose:
If type [D.3.300] or [D.4.300] or [D.6.300] or [D.7.300 the max. stroke is
set to 300mm (11.81in).
Actuator FMS-winderGLIDE BKS.D.7
This actuator is driven by a DC motor. Additional parameters will be
activated automatically.
Acceleration [Accelara]
Purpose
:
The acceleration ramp is only used in combination with the BKS.D.7. This
parameter determines the acceleration and deceleration ramp of the motor.
The DC motor driver uses the same ramp for both. The parameter defines the
required time span to reach the maximum speed and vice versa.