Operating Manual Web Guide Controller BKS309
23.07.2019
19
8
Configuration via operating panel
8.1
Operating parameters
To access the meu for the operating parameters the web guide controller must be in the
manual mode.
Press the
key for longer than 3 sec. The LED will be on and the first parameter
will be displayed.
With the
buttons the parameter list can be scrolled up and down. By pressing
the
button again you will enter the parameter setting mode. The select parameter
on the display flashes indicating that it can be modified with the buttons
To save the changes, press
.
8.2
List of operating parameters
Description
Parameter LCD
Unit
Min
Max
Selection
Factory
Adjust
Reference
Position
Ref Pos
mm
-5.00 +5.00 - 0.00
Set
Reference
Mode
Ref Mode
-
-
- Manual
Auto
Manual
Save the
Reference
Position
SaveRef
-
-
- No
Yes
No
Dead
band
DeadBand mm 0.0
2.0
- 0.1