Operating Manual Web Guide Controller BKS309
23.07.2019
30
Action:
[Not Set]
Purpose: If
[Not Set] is chosen, all parameters stay as set by the user.
Action:
[Yes]
Purpose: If
[Yes]
is chosen, the default parameters are loaded.
8.4
System parameters
To access the menu for system parameters, the web guide controller must be in the
Manual Mode.
Press the
and
buttons together for longer than 3 sec. The LED will light and
the first parameter will be displayed
With the
buttons the parameter list can be scrolled up and down. By pressing
the
button again you will enter the parameter setting mode. The select parameter
on the display flashes indicating that it can be modified with the buttons
To save the changes, press
.
8.5
List of System parameters
description
Parameter LCD
Unit
Min
Max
Selection
Factory
Offset
Centre
Offset><
-
-
-
-
4)
Position
Detection
PosDetec
-
-
- Potentio
One Hal
Two Hal
4)
Centre
Position
CentrPos step
s
0.0 10‘000
-
4)
Right
Limit
RightLim step
s
0.0 10‘000
-
4)