INSTALLATION

Continued

Venting with Two 90° Elbows

Vertical (V)

Horizontal (H

1

)

Horizontal (H

1

) + 

Horizontal (H

2

)

5' min.

2' max.

6' max.

6' min.

4' max.

12' max.

7' min.

6' max.

18' max.

8' min.

8' max.

20' max.

20' max.

8' max.

20' max.

45° Elbow

HORIZONTAL SYSTEM INSTALLATION USING TWO 90° ELBOWS

The following configurations show the minimum vertical rise requirements for a horizontal 

system using two 90° elbows.

Venting with Two 90° Elbows

Figure 12 - Horizontal Termination Configuration for Venting Using Two 90° Elbows 

with Termination at 90° with Fireplace

45° Elbow

Figure 11 - Horizontal Termination Configuration for Venting Using Two 90° Elbows

Vertical (V)

Horizontal (H

1

) + 

Horizontal (H

2

)

5' min.

6' max.

6' min.

12' max.

7' min.

18' max.

8' min.

20' max.

20' max.

20' max.

f i r e - p a r t s . c o m

Содержание CD32M-LS

Страница 1: ...ht any appliance Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer service agency or the gas supplier INSTALLER Leave this manual with the appliance CONSU...

Страница 2: ...40 MH Series in Canada This fireplace is only for use with the type s of gas indicated on the rating plate A conversion kit is supplied with the fireplace State of Massachusetts The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts SAVE THIS BOOK This book is valuable In addition to instructing you on how to install and maintain your appliance it al...

Страница 3: ... of a space that may not normally be used and pro vides a wider and more efficient range for radiant heat transfer 2 Consider a location where the fireplace would not be affected by drafts air con ditioning ducts windows or doors 3 A location that avoids the cutting of joists or roof rafters makes ventilation installa tion easier In selecting a location the following precau tions must be observed ...

Страница 4: ...ent even though no odor exists Make certain you read and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this fireplace WARNING Any change to this fireplace or it s controls can be dangerous Do not modify this fireplace under any circum stances Any parts removed for servicingmustbereplacedprior to operating fireplace WARNING Do not use a blow...

Страница 5: ...t try to light any appliance do not touch any electrical switch do not use any phone in your building immediately call your gas supplier from a neighbor s phone Follow the gas sup plier s instructions if you cannot reach you gas supplier call the fire department 3 Never install the fireplace in windy or drafty areas where curtains or othercombustible flammable objectscan make contact with the fire...

Страница 6: ... is supplied If you plan to install an optional blower do not forget to wire the fireplace outlet when framing PRE INSTALLATION PREPARATION Mantel Depth Mantel From Top of Opening 1 14 A 16 2 12 B 14 3 10 C 12 4 8 D 10 5 6 E 8 6 4 F 6 7 2 G 4 CAUTION Do not block required air spaces with insula tionoranyothermaterial Donot obstruct the effective opening of the appliance with any type of facing mat...

Страница 7: ...wnward as this may cause excessive tempera tures which could cause a fire PRE INSTALLATION PREPARATION Continued Figure 3 Framing Dimension Figure 4 Corner Installation WARNING Horizontal sec tions of this vent system require a minimum clearance of 2 from the top of the pipe and 1 mini mum to the sides and bottom Vertical sections of this system require a minimum of 1 clear ance to combustible mat...

Страница 8: ...er than 50 000 36 91 cm in Canada if greater than 100 000 K clearance to a mechanical air supply inlet In Canada 6 ft 1 83m minimum In US 3 ft 91 cm above if within 10 ft 3 m horizontally L clearance above paved side walk or a paved driveway located on public property 84 213 3 cm minimum M clearance under veranda porch deck 12 30 5 cm minimum N clearance above a roof shall extend a minimum of 24 6...

Страница 9: ...n line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than 1 2 in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspection the inspector obse...

Страница 10: ...cking Lugs Vertical Flue Restrictor For Vertical Venting Application WARNING Read all instruc tionscompletelyandthoroughly before attempting installation Failure to do so could result in serious injury property dam age or loss of life Operation of improperly installed and main tained venting system could result in serious injury property damage or loss of life NOTICE Failure to follow these instru...

Страница 11: ...that is over 3 ft support pipe every 3 ft using metal wall straps Vertical to horizontal pipe must be kept at a 1 ft to 4 ft ratio with a maximum run of no more than 20 ft If an offset is necessary in attic to avoid obstruction it is important to support vent pipe every 3 ft to avoid excessive stress on elbows and possible separation see Figure 8 INSTALLATION Continued Figure 8 Vertical Terminatio...

Страница 12: ...mits TYPICAL CORNER INSTALLATION Recommended Applications Corner ground floor installation Ground floor installation where pipe vents horizontally through wall over 12 horizon tal pipe Basement installation where one foot clear ance from ground to termination is possible Vertical V Horizontal H 29 3 4 17 max Horizontal High Wind Square Termination Wall Firestop 45 Elbow Adjustable Pipe 12 Max Squa...

Страница 13: ...WO 90 ELBOWS The following configurations show the minimum vertical rise requirements for a horizontal system using two 90 elbows Venting with Two 90 Elbows Figure 12 Horizontal Termination Configuration for Venting Using Two 90 Elbows with Termination at 90 with Fireplace 45 Elbow Figure 11 Horizontal Termination Configuration for Venting Using Two 90 Elbows Vertical V Horizontal H1 Horizontal H2...

Страница 14: ... Drop a plumb line down from ceiling to position of fireplace exit flue Mark center point where vent will penetrate ceiling Drill a small locating hole at this point Drop a plumb line from inside roof to locating hole in ceiling Mark center point where vent will penetrate roof Drill a small locating hole at this point Figure 13 Offset with Wall Strap and 45 Elbows 45 Elbow Wall Strap Roof Flashing...

Страница 15: ...d High Wind Termination Shown Note Install restrictor into inner collar of fireplace as shown Vertical V1 Horizontal H 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max Note Vertical V1 Vertical V2 40 max Figure 16 Vertical Venting Configuration Using Two 90 Elbows Vertical Round High Wind Termination Shown Note Install restrictor into inner collar of fireplace as shown 45 Elbow 45 Elbow Venting ...

Страница 16: ... Figure 20 Figure 20 Gas Control Valve ON OFF Knob Pilot Adjustment Inlet Pressure Outlet Pressure Flame Adjustment Knob Pilot Gas Line Do Not Kink To Pilot Burner To Main Burner GAS LINE HOOK UP WARNING Gas line hook up should be done by your gas supplier or a qualified service person WARNING Before you pro ceed makesureyourgassupply is OFF An equipment shutoff valve has been included in fireplac...

Страница 17: ... ap ply commercial leak detection fluid to all gas joints Bubbles forming show a leak Correct all leaks at once Do not operate any appliance if a leak is detected INSTALLATION Continued Figure 22 Gas Line Routing Gas Routing Right Side Not Shown Side of Fireplace Front Face Figure 23 Sediment Trap Sediment Trap Not Supplied Incoming 1 2 Gas Line Permitted By Local Codes 3 Min 7 6 cm PILOT ADJUSTME...

Страница 18: ...m glass door center bracket Slide screen rod to left or right of fireplace until one end is free to completely remove screen from fireplace 3 Undo latches located on top and bottom of firebox see Figure 26 Carefully swing door to the left Glass door is securely mounted to firebox with 5 screws Figure 28 Control Valve Terminals To Optional Remote Accessory To Wall Thermostat Wire terminals Remote R...

Страница 19: ... according to instructions for fireplace model numbers 1 Find and place log 1 rear log The log has a flat bottom with a slit cut into it to sit over the grate flap see Figure 29 2 Rest log 2 front log on pins on front part of grate see Figure 30 4 Place log 4 right log onto the landing on right side of front log as shown in Figure 32 4 Figure 32 Installing Log No 4 5 Place log 5 base log onto fron...

Страница 20: ...arances are observed see Clear ances to Combustibles page 6 Louvered openings must not be obstructed and upper and lower panels must remain accessible for service Use only heat resistant noncom bustible mortar or adhesive when securing decorative facing materials INSTALLATION Continued FACE EXTENSION Model CD32M LS comes equipped with a front face extension Front face extension would add 3 1 2 to ...

Страница 21: ... bracket by placing plastic control shaft forward through round opening in switch bracket see Figure 36 6 While supporting speed control secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise until it is tight against front panel Place provided control knob on shaft 7 Turn on power to duplex outlet if previously turned off per warning in column 1 8 Plug in blower ...

Страница 22: ...gure 38 in order to sense temperature and properly operate The blower will be held in position against the back wall by the magnets incorporated onto the blower housing see Figure 38 4 Be certain that all wire terminals are securely attached to terminals on blower motor and that the screw retaining the green ground wire is tight 5 Mount speed control box against mounting plate provided in lower fi...

Страница 23: ...n clean burning flame across burner see Figure 41 page 24 If adjustment is necessary you can restore proper flame setting by loosening air shutter screw and rotating air shutter until proper setting is achieved see Figure 42 page 24 Air shutter setting is 1 8 open for natural gas and full open for propane LP gas 10 Blower will only run when speed control knob is in the ON position and thermal swit...

Страница 24: ...r obstruct flow of combustion and ventilation air Keep front of fireplace clear of all obstacles and materials FOR YOUR SAFETY READ BEFORE LIGHTING WARNING Ifyoudonotfollow these instructions exactly a fire or explosion may result caus ing property damage personal injury or loss of life A This appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions exa...

Страница 25: ...Indicator Gas Control Knob HI LO Knob Figure 44 Pilot Thermocouple Pilot Burner Piezo Ignitor Thermopile TO TURN OFF GAS TO APPLIANCE 1 Turn off wall switch if installed 2 Turn off all electric power to appliance if service is to be performed 3 Open bottom access louver 4 Slide selector switch to OFF position 5 Push in gas control knob slightly and turn clockwise to OFF Do not force 6 Close bottom...

Страница 26: ...rial from burner and place them aside in a safe place 5 Replace main burner orifice with burner orifice included in conversion kit 6 Locate air shutter at end of burner mani fold Loosen screw and adjust air shutter to proper setting see Burner Flame Adjustment page 23 Retighten screw 7 Remove pilot hood by pulling up until it disengages from barrel Do not remove the retainer clip see Figure 45 8 R...

Страница 27: ...ion If anyinformationistheseinstruc tions is not followed correctly a fire explosion or production of carbon monoxide may result causing property damage per sonal injury or loss of life The qualified service technician is responsible for the proper in stallation of this conversion kit GAS CONVERSION Continued SPECIFICATIONS CD32M LS AND CD32MB LS Natural Gas Rating 12 000 18 000 Btu Hr Gas Type Na...

Страница 28: ...nd thermocouple are tight and secure 4 Check thermocouple with millivolt meter Take reading at thermocouple terminals of gas valve with remote control off It should read 18 millivolts minimum Re place faulty thermocouple if reading is below specified minimum 1 Check remote wires for proper connections Place jumper wire across ter minals at remote control If burner comes on re place remote If okay ...

Страница 29: ...ubleshooting If so contact FMI PRODUCTS LLC at 1 866 328 4537 When calling please have your model and serial numbers of your fireplace ready You can also visit FMI PRODUCTS LLC s web site at www fmiproducts com ACCESSORIES NOTE Allaccessoriesmaynotbe available for all fireplace models Purchase these accessories from an au thorized dealer If they can not supply these accessories call FMI PRODUCTS L...

Страница 30: ...roducts com 125204 01C 30 6 7 19 18 10 23 24 34 2 17 8 21 2 21 6 21 4 21 5 21 3 21 1 1 9 16 3 14 4 20 5 15 13 11 35 36 22 37 39 38 25 12 26 30 27 28 29 33 31 32 PARTS MODEL CD32M LS AND CD32MB LS fire parts com ...

Страница 31: ... 4 109406 01 Crossover Log Log 3 1 21 5 109405 01 Left Top Log Log 6 1 21 6 109408 01 Right Top Log Log 4 1 22 11102 Screw 8 32 x 3 8 PPH Zinc 2 23 11105 Screw 10 x 1 2 Zinc 9 24 11179 Screw 10 24 x 1 4 Zinc 4 25 11237 Screw Trilab M4 x 8 mm 1 26 14389 HI LO Sit Valve Natural Gas 1 27 14492 Piezo Ignitor 1 28 14500 Brass Fitting 2 29 14253 Flexible Connector 1 30 14511 Ignitor Bracket 1 31 14528 B...

Страница 32: ...alfactoryreplacementparts Failuretouseoriginalfactoryreplacementpartsvoidsthiswarranty Travel handling transportation diagnostic material laborandincidentalcostsassociatedwithwarrantyrepairs unless expressly covered by this warranty are not reimbursable under this warranty and are the responsibility of the owner All warranty will be voided if this product is used with a thermostat Excluded from th...

Отзывы: