Page 1: ...600A767 03 M O D E L 3 2 6 R a d i a n t C o n v e c t o r G a s F i r e Sun Fire I N S T A L L E R G U I D E Please keep in a safe place for future reference...

Page 2: ...ur Valor AdviceLine will be pleased to help Please telephone 0345 626341 In UK local call rates apply This appliance is for use with natural gas G20 This appliance is for use in the United Kingdom GB...

Page 3: ...ting 9 Reference Pressure Check 9 Outer Case Fitting 9 Operation Checks 10 Control Settings 10 Spillage Check 10 Dress Guard Fitting 10 Final Review of Installation 11 Servicing 11 Radiants Replacemen...

Page 4: ...all gas appliances are installed by competent persons in accordance with the current edition of the Gas Safety Installation and Use Regulations Failure to install the appliance correctly could lead t...

Page 5: ...rd requires 16 500mm2 This appliance is suitable in both cases The chimney should be one or two storeys high but not less than 3m vertical height and be correctly terminated No mortar fangs between th...

Page 6: ...clearance from the top surface of the appliance to the underside of any shelf made from wood or other combustible materials is as follows For a shelf up to 150mm deep Minimum height 203mm For a shelf...

Page 7: ...right trims 3 3 7 Check ignition spark Before attempting to install it is worth checking that the piezo electric spark ignition system operates satisfactorily Temporarily refit the control knob To ini...

Page 8: ...s satisfactory 3 4 3 Wall mounting 1 The closure plate must be fitted and sealed to the fireplace opening using a suitable heat resistant material If necessary cut the closure plate Leave the closure...

Page 9: ...the pipe with tape after connection 4 3 2 Provision for isolation of the gas supply must be provided upstream of the appliance for safety and servicing 4 3 3 The supply pipe must be of a rigid materia...

Page 10: ...4 Place the smoke match tube horizontally under the top lip of the radiant box and at least 50mm away from the sides of the radiant box See figure 8 The installation is satisfactory if the smoke is dr...

Page 11: ...of the radiant box 7 1 3 Replace the dress guard Locate the bottom of the dress guard in the two holes in the apron Engage the two spring projections at the top of the guard in the slots under the fr...

Page 12: ...ting the split pin 7 7 TO GREASE THE GAS TAP 7 7 1 Remove the gas tap complete with piezo generator see section 7 5 7 7 2 Remove the two screws and shakeproof washers securing the piezo generator Care...

Page 13: ...B Piezo generator 1 536939 C Injector Upper Bray cat 28 size 120 1 544619 D Injector lower Bray cat 28 size 250B 1 545199 E Pilot unit 1 545949 F Electrode lead 1 544629 G Inlet elbow 1 532519 H Cont...

Page 14: ...ds Valor is a member of the Society of British Gas Industries which works to ensure high standards of safety quality and performance Careful Installation Valor is a Corgi registered company All our ga...