INTRODUCTION
WARNING: This product con
-
tains and/or generates chemicals
known to the State of California
to cause cancer or birth defects
or other reproductive harm.
Model CD32M-LS or CD32MB-LS is a heat
circulating gravity direct vent fireplace with
sealed combustion chamber. This fireplace
uses millivolt gas control valve and millivolt
ignition system.
This fireplace is convertible with the standard
setup as natural gas. Conversion may be
performed by the OEM mobile home builder
or by a qualified service person on-site. If
you are uncertain as to what gas your unit is
equipped for, please check the rating plate
located inside of the appliance opening or
consult your mobile home supplier or your
local distributor of FMI PRODUCTS, LLC.
NOTICE: Check local building
codes for area requirements
before installing this appliance.
BEFORE YOU BEGIN
Before beginning the installation of your
appliance, read these instructions through
completely.
Figure 1 - Common Fireplace Locations
FULL
PROJECTION CORNER
INSTALLATION
FLUSH
INSTALLATION
To determine the safest and most efficient
location for your fireplace, consider the fol
-
lowing guidelines:
1. The location must allow for proper clear-
ances (see Figure 1).
• Flush installation is recommended where
living space is limited.
• Projected installation may be ideal for a
new addition to an existing finished wall.
• Corner installation makes use of a space
that may not normally be used and pro-
vides a wider and more efficient range
for radiant heat transfer.
2. Consider a location where the fireplace
would not be affected by drafts, air con-
ditioning ducts, windows or doors.
3. A location that avoids the cutting of joists
or roof rafters makes ventilation installa-
tion easier.
In selecting a location, the following precau-
tions must be observed:
This FMI PRODUCTS, LLC fireplace and its
components are safe when installed accord-
ing to this installation manual and operated as
recommended. Unless you use FMI PROD-
UCTS, LLC components designed and tested
for this fireplace system,
YOU MAY CAUSE
A SAFETY HAZARD!
The FMI PRODUCTS, LLC warranty will
be voided by, and FMI PRODUCTS, LLC
disclaims any responsibility for the following
actions:
A) Modification to the fireplace, components,
doors, blower, fans or vent system.
B) Use of any component part not manufac-
tured or approved by FMI PRODUCTS,
LLC in combination with a FMI PROD-
UCTS, LLC fireplace system.
Proper installation is the most important step
in ensuring safe and continuous operation of
the fireplace. Consult the local building codes
as to the particular requirements concerned
with the installation of all factory built fire
-
places. This fireplace, when installed, must be
electrically grounded in accordance with local
codes or in the absence of local codes, with
the
National Electrical Code, ANSI/NFPA 70.
The installation must conform with local codes
or, in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1.
This
appliance complies with ANSI Z21.88.
SELECTING LOCATION