9. ELECTRICAL POWER REQUIREMENTS
The following table describes:
• The electrical power requirements for each Fluidmesh hardware
device type.
• Which Fluidmesh hardware devices are capable of receiving power
through an IEEE 802.3 Ethernet port (whether from a power-
supplying device like a compatible network switch, or from a power-
over-Ethernet (PoE) injector), or through a DC IN power supply
port, or both.
• The specific voltage-variation tolerances of each Fluidmesh radio
transceiver unit type.
Table 9. Individual power requirements (FM 1000 Gateway and FM
10000 Gateway)
Required input power
FM 1000
Gateway
FM 10000
Gateway
DC IN
12 Vdc (from mains AC power adapter
producing a minimum of 60W (12V/5A)).
X
AC IN
Unit may be equipped with multiple 275W
redundant AC power supply units (input
power: 100 Vac to 240 Vac at 50 Hz to 60 Hz).
X
Unit may be equipped with single 250W non-
redundant AC power supply unit (input power:
100 Vac to 240 Vac at 50 Hz to 60 Hz).
X
Table 10. Individual power requirements (FM PONTE 50 to FM 4200
MOBI)
FM
PONTE
50
FM
1200
VOLO
FM
1300
OTTO
FM
3200
BASE
FM
3200
ENDO
FM
3200
+GPS
FM
3200
DEPOT
FM
4200
MOBI
PoE
24V
passive
PoE
X
X
48V
passive
PoE
X
X
X
X
X
IEEE
802.3af
PoE
(voltage
range at
PD: 37V to
57V)
X
X
X
X
X
X
Fluidmesh 4200 FIBER
© Fluidmesh Networks LLC
Page 165 of 180