Flottweg
Flottweg-SIMP-CONTROL®
“Product feed off”:
If the nominal torque value (W) is exceeded for the set value, the control switches off the
product feed, to prevent the clogging of the centrifuge.
The parameter is entered in percent of the set nominal torque value (W); the value
should exceed the nominal torque value (W) sufficiently depending on the separation
task.
A time delay is entered in the control which ensures that a short torque peak does not
immediately lead to a switch-off of the product feed.
“Bowl drive off”:
When this torque value is reached, the control will switch off the bowl drive to prevent
the clogging of the centrifuge.
The scroll drive is not switched off to clear the centrifuge.
The parameter is entered in percent of the available drive torque; the value should
exceed the switch-off point “Product feed off” sufficiently depending on the separation
task.
A time delay is entered in the control which ensures that a short torque peak does not
immediately lead to a switch-off of the bowl drive.
Fixed value differential speed (Y2)
With this parameter, a fixed value can be set for differential speed.
If this fixed value is selected by the machine control, the machine operates constantly at
this differential speed (without control!).
This mode of operation makes sense during rinsing processes or when the bowl drive is
switched off, e.g. while the machine is running out.
The parameter is to be entered in percent; the resulting differential speed can be read off
the speed display.
U
k-
6
_
2
_
3
x8
-S
IM
P
-O
P
_
0
8
1
2
0
9
–
P
re
_
W
O
H
Содержание TRICANTER Z 8E
Страница 5: ...Flottweg 1 GENERAL Uk1 allg_030107 Pre...
Страница 15: ...Flottweg 2 OPERATION Uk2 allg_030107 Pre...
Страница 24: ...Flottweg 3 LUBRICATION AND INSPECTION Uk3 allg_030107 Pre...
Страница 37: ...Flottweg 4 OPERATING TROUBLES Uk4_1 allg_030107 Pre...
Страница 44: ...Flottweg 5 TABLES AND DIAGRAMS Uk5 allg_030107 Pre...
Страница 46: ...Flottweg 6 APPENDIX Uk6 allg_030107 Pre...