2.4/4
9. Input of impeller disc positions
The impeller disc intervals have to be defined by the user. A total of ten intermediate points
can be stored on the PLC for remote adjustment. The adjustment begins with the minimum
impeller disc diameter.
The table shows the impeller disc diameters marked on the machine.
Values without brackets should be used as intermediate points.
Z3E
160
165
170
175
180
185
190
195
200
205
Z4E
220 (225) 230
235
240
245
250
255
260 (265) 270 (275) 280
Z5E
280 (285) 290 (295) 300 (305) 310 (315) 320 (325) 330 (335) 340
(345) 350 (355) 360
365
Z6E
358
360 (365) 370 (375) 380
390
400 (410) 420
430
440
450
Z8E
420 (425) 430 (435) 440 (445) 450 (455) 460 (465) 470 (475) (480)
485 (490) (495) 500 (505) (510) 515 (520) (525) (530) 532
S3E
115
120
125
130
135
138
140
143
145
146
S4E
200
205
210
215
220
225 (230) 235
240
245
248
S6E
295
300
305
310 (315) 320
325
330
335
340
346
Adjust the impeller disc diameter using the
handwheel on the actuator.
Enter the impeller disc diameter in “Output” (3),
then enter the current input value (4) in the
“Input” column (5).
10. After completing the entries, click the button
to switch to automatic operation
.
U
k2
_
4
_
a
u
m
a
_
2
1
0
2
1
7
-L
i
4
5
3
Содержание TRICANTER Z 8E
Страница 5: ...Flottweg 1 GENERAL Uk1 allg_030107 Pre...
Страница 15: ...Flottweg 2 OPERATION Uk2 allg_030107 Pre...
Страница 24: ...Flottweg 3 LUBRICATION AND INSPECTION Uk3 allg_030107 Pre...
Страница 37: ...Flottweg 4 OPERATING TROUBLES Uk4_1 allg_030107 Pre...
Страница 44: ...Flottweg 5 TABLES AND DIAGRAMS Uk5 allg_030107 Pre...
Страница 46: ...Flottweg 6 APPENDIX Uk6 allg_030107 Pre...