17 SuperUser mode
FLUXUS F808
17.9 Display of the totalizer sum
147
UMFLUXUS_F808V2-2EN, 2020-06-25
17.9
Display of the totalizer sum
The totalizer sum of both flow directions can be displayed in the upper line during the measurement.
• Select
Special Funct.\SYSTEM settings\Measuring\Miscellaneous
.
• Press ENTER until the menu item
Show
ΣQ
is displayed.
• Select
on
to activate the display of the totalizer sum,
off
to deactivate it.
• Press ENTER.
If the display of the totalizer sum is activated, the sum
Σ
Q of the totalizers can be displayed in the upper line during the
measurement.
17.10 Display of the last valid measured value
If the signal is not sufficient for a measurement,
UNDEF
is normally displayed. Instead of UNDEF, it is also possible to dis
-
play the last valid measured value.
• Select
Special Funct.\SYSTEM settings\Measuring\Miscellaneous
.
• Press ENTER until the menu item
Keep display val
is displayed.
• Select
on
to activate the display of the last valid measured value,
off
to deactivate it.
• Press ENTER.
17.11 Displays during the measurement
Besides the normal information, see section 9.4, the following parameters can be displayed during the measurement in
the SuperUser mode:
Special Funct.\SYSTEM settings\Measuring\Miscellaneous\Show ΣQ
Fig. 17.2: Display of the totalizer sum
Special Funct.\SYSTEM settings\Measuring\Miscellaneous\Keep display val
display
explanation
t
transit time of the measuring signal in the fluid
c
sound speed
REYNOLD
Reynolds number
VARI A
standard deviation of the signal amplitude
VARI T
standard deviation of the transit time of the measuring signal
dt-norm
transit time difference standardized to the transducer frequency
density of the fluid
ΣQ
13.2 m3