PRIMARY DATA MONITOR ING
The options available in the Primary Data Monitoring submenu are: Disabled, Cellular Eagle 2.0, RS 485 Modbus
RTU, Ethernet SNMP, Ethernet Modbus (RTU / TCP) and Ethernet Eagle 2.0. A brief description of the application
for each method is listed in the following bullet points:
Cellular Eagle - selected when the system is purchased with a cellular modem and will be monitored by
the Flash Technology NOC.
RS 485 Modbus RTU - used to connect via serial cable to an external monitoring device on site that
supports Modbus protocol. (Not currently available)
Ethernet SNMP - used to connect via Ethernet to a server that is able to monitor SNMP traps.
Ethernet Modbus (RTU / TCP) - used to connect via Ethernet to an external monitoring device on site or
to a server connected to the network that is able to monitor Modbus devices. (Not currently available)
Ethernet Eagle - selected when the system will be connected to the Flash Technology NOC
ALTERNATE DATA MONITORING
Alternate Data Monitoring allows for a secondary monitoring method. All options available in the Primary Data
Monitoring menu are available in the Alternate Data Monitoring menu.
Note: Monitoring Options are mutually exclusive. Example: If RS 485 Modbus RTU is selected in either menu, it is
removed from the available options in the other menu.
Ethernet SNMP, if used, must be selected as the Primary Data Monitoring method.