Flash Technology
Revision A - 2/13/2020
48
Table 3-4: Monitoring Configuration Menu Options
Load Factory Default
Yes /No
Yes Confirm?
Default of Primary / Alternate Monitoring
Local Ethernet Configuration
IP Address Mode
Static
Dynamic
IP Address
XXX.XXX.XXX.XXX
Subnet Mask
XXX.XXX.XXX.XXX
Default Gateway
XXX.XXX.XXX.XXX
MAC Address
XXXXXXXXXXXX
Commit Settings
Yes /No
Yes Confirm?
Primary Data Monitoring
Monitoring Method: Disabled
Monitoring
Method:
Cellular
Eagle 2.0
Autoupdate: XX Hours - XX
Minutes
Hours (Enter Value Ranging From 0 - 24)
Minutes (Enter Value Ranging From 0 -
59)
Primary Server IP Address (Enter IP Address)
Primary Server Port 54630
Alternate Server IP Address (Enter IP Address)
Alternate Server Port 54630
Listen Port 54631
Sim Card: (AT&T Direct, AT&T
ROW, AT&T ROW2 or
Customized)
1
Select AT&T Direct (SIM is Blue/White
Front, Orange Back)
Select AT&T ROW (Rest Of World) (SIM
Is Solid White)
Select AT&T ROW2 (Rest Of World 2)
(SIM Is Solid White)
Select Customized if you know your APN
and are connecting to a third party NOC
Monitoring
Method:
RS 485
Modbus
RTU
Autoupdate: Disabled
Baud Rat: 9600
Station Address: Default is 2 (Enter Value Ranging From 0 – 255)
Monitoring
Method:
Ethernet
SNMP
2
Autoupdate: XX Hours - XX
Minutes
Hours (Enter Value Ranging From 0 - 24)
Minutes (Enter Value Ranging From 0 -
59)
Primary Server IP Address (Enter IP Address)