TemplateA4_v20130506
15
Alphabetic glossary of abbreviations in terminal plan.
Note: mentioned switch settings are in current-free, un-switched situation.
accessory
(SPC Extension volume, pressure analog, optional)
COM
COM interface; serial port
COM
The common port
data
(Data protocol, optional)
drs
(Diaphragm rupture sensor, optional)
extra low voltage
Protective low voltage
fault
Error message, common error message Displayed switch setting is error.
F1/2 MS1/2
(Motor circuit-switch 1/2; Motor circuit-switch combination 1/2, SPCx-hw)
gs
(Gas sensor, optional Gas sensor flexible connection assembly)
high voltage
Voltage as per markings on the automat
mains supply
Power feed
mpl
(Minimum pressure limiter, optional)
M3/3.1 V3/3.1
Motor 3 (top-up, optional) / 3.1 (drainage, optional); valve 3 (top-up) / 3.1
(drainage, optional)
M1 V4 K1/MS1
Motor 2 (pressure increase); valve 5 (not applicable); switch 2 / motor circuit-switch combination 2,
SPCx-hw
M2 V5 K2/MS2
Motor 2 (pressure increase); valve 5 (not applicable); switch 2 / motor circuit-switch combination 2,
SPCx-hw
niveau
Level, content
ohmic load
Ohmic load, resistance
option
(not applicable)
pressure
Pressure
pwm
(Impulse water meter, optional)
ps
(Pressure switch; level switch min. level, top-up pump, optional)
refill / drain
Top-up / (drain , optional)
sensors
Sensors
tc
(Temperature switch, optional)
V1; 1.1
Valve 1; 1.1; parallel, air release valve (pressure drop)
V2
Valve 2; air release valve
(pressure drop)
V2.1
Valve 2.1 (not applicable)
5.3 Type key Pump control unit
Key:
AB - C - D
E.g.:
DP80 - 1 - 50
Nom. frequency of the operating voltage (Hz):
50
= 50 Hz;
60
= 60 Hz
Pump manufacturer:
Module version:
Performance class:
MP
= Monopump;
DP
= Duopump
M
;
2
;
10
;
20
;
60
;
80
;
90
;
100
;
130
1
;
2
;
3
;
4
;
5
5.4 Type key Controller unit
Key:
SPC
x - y - A - B - C - D - E
SPC
1.2
- hw - 1 - 1 - 7 - 1 - 0
SPC
1.2
- lw
Phase monitoring/SPC-extension module, Ananlogue signalling:
0
= Not present;
Start type:
Number of motors:
Hardware version
Nominal current range:
Voltage:
1
= 400 V ± 10 % / 3 N PE / 50/60 Hz
Output range:
1
= Direct start;
2
= Soft start
1
= 1 motor;
2
= 2 motors
1
= 1.1 - 1.6;
2
= 1.4 - 2.0;
3
= 1.8 - 2.5;
4
= 2.2 - 3.2;
5
= 2.8 - 4.0;
6
= 3.5 - 5.5;
7
= 4.5 - 6.3;
8
= 5.5 - 8.0;
23
= 4.0 - 6.3;
24
= 6.3 - 10.0;
25
= 8.0 - 12.0
lw
= low output
hw
= high output
MP; DP / P ≤ 2.2 kW
1
= Present
9
= 7.0 - 10.0;
20
= 1.0 - 1.6;
21
= 1.6 - 2.5;
22
= 2.5 - 4.0;
N
N
N
E.g.:
MP / P ≤ 4,0 kW
;
DP / P ≤ 8,0 kW
ENG