4-43
Using the Model 3095FT User Interface Software
Sys Admin
Options
The Options screen provides two functions. The Communication
Options section displays communication options between the User
Interface Software and the attached Model 3095FT transmitter when
reading or sending data. The Log Options section defines which logs
will be collected when “collect default logs” is selected.
Communication Options
Initial Device Address
Indicates the device address for the attached Model 3095FT transmitter.
Number of Retries
Indicates the number of times the User Interface Software attempts to
complete a communication task before declaring a communications
failure. Under most circumstances, this value should never be less than
three. (Valid Range: 0–99. Default Value: 3.)
Log Buffer Size
This value should not be changed unless directed by Rosemount
Customer Central.
Log Options
View:
View Short Date is an option that changes the collected log data
between long date (95-07-28) and short date (07-28). View Short Time is
an option that changes the collected log data between long time
(06:43:48) and short time (06:43). An
indicates that the short option
is selected.
Print:
Print Text indicates the log will be stored as ASCII data, while
print comma delimited is used when the log will be imported into a
spreadsheet. An
indicates which option is selected.
Collect:
The collect options define which logs will be automatically
collected when “collect default logs” is selected, either via the toolbar or
via the menu selection (Logs, View Transmitter Data, Default).
FIGURE 4-36. Options Screen.
30
95
-30
950
04
7
Содержание 3095FT
Страница 1: ...R Model 3095FT HART Flow Transmitter 00809 0100 4015 English Rev B1...
Страница 2: ......
Страница 4: ......
Страница 45: ...3 13 Options and Accessories 3051 1006D03A FIGURE 3 5 Recharging the Battery 15 to 36 V dc 500 mA minimum...
Страница 98: ...Rosemount Model 3095FT HART Flow Transmitter 4 50...
Страница 117: ...5 19 Troubleshooting and Maintenance FIGURE 5 2 Replacing the Remote Power Supply Battery...
Страница 118: ...Rosemount Model 3095FT HART Flow Transmitter 5 20...
Страница 146: ...Rosemount Model 3095FT HART Flow Transmitter 7 24...
Страница 147: ...Appendix A 1 A Model 3095 Explosion Proof Installation Drawing Factory Mutual Drawing Number 03095 1025 Rev G...
Страница 148: ...Rosemount Model 3095FT HART Flow Transmitter A 2...
Страница 149: ...A 3 Appendix A...
Страница 150: ...Rosemount Model 3095FT HART Flow Transmitter A 4...
Страница 151: ...Appendix B 1 B Index of I S F M for 3095 and Index of I S F M for 03095 5000 Drawing Numbers 03095 1020 and 03095 5000...
Страница 152: ...Rosemount Model 3095FT HART Flow Transmitter B 2...
Страница 153: ...B 3 Appendix B...
Страница 154: ...Rosemount Model 3095FT HART Flow Transmitter B 4...
Страница 155: ...B 5 Appendix B...
Страница 156: ...Rosemount Model 3095FT HART Flow Transmitter B 6...
Страница 157: ...B 7 Appendix B...
Страница 158: ...Rosemount Model 3095FT HART Flow Transmitter B 8...
Страница 159: ...Appendix C 1 C Model 3095 Explosion Proof Installation Drawing CSA Drawing Number 03095 1024 Rev D...
Страница 160: ...Rosemount Model 3095FT HART Flow Transmitter C 2...
Страница 161: ...C 3 Appendix C...
Страница 162: ...Rosemount Model 3095FT HART Flow Transmitter C 4...
Страница 163: ...Appendix D 1 D Index of I S CSA for 3095 and Index of I S CDA for 03095 5000 Drawing Numbers 03095 1021 and 03095 1031...
Страница 164: ...Rosemount Model 3095FT HART Flow Transmitter D 2...
Страница 165: ...D 3 Appendix D...
Страница 166: ...Rosemount Model 3095FT HART Flow Transmitter D 4...
Страница 167: ...D 5 Appendix D...
Страница 168: ...Rosemount Model 3095FT HART Flow Transmitter D 6...
Страница 183: ......